EasyManua.ls Logo

Mitsubishi Electric MXZ-5C42NAHZ User Manual

Mitsubishi Electric MXZ-5C42NAHZ
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL & SERVICE MANUAL
CONTENTS
TECHNICAL CHANGES
.........................................
2
1. SAFETY PRECAUTION
....................................
3
2. OVERVIEW OF UNITS
......................................
6
3. SPECIFICATIONS
............................................
10
4. DATA
................................................................
14
5. OUTLINES AND DIMENSIONS
......................
36
6. WIRING DIAGRAM
.........................................
40
7.
NECESSARY CONDITIONS FOR SYSTEM CONSTRUCTION
....
47
8. TROUBLESHOOTING
....................................
52
9.
PRECAUTIONS AGAINST REFRIGERANT LEAKAGE
....
141
10. DISASSEMBLY PROCEDURE
......................
142
No. OCH573
REVISED EDITION-E
MXZ-4C36NAHZ MXZ-4C36NAHZ-U1
MXZ-5C42NAHZ MXZ-5C42NAHZ-U1
MXZ-8C48NAHZ MXZ-8C48NAHZ-U1
MXZ-8C48NA MXZ-8C48NA-U1
MXZ-8C60NA-U1
PAC-MKA50BC
PAC-MKA30BC
PAC-MKA51BC
PAC-MKA31BC
HFC
utilized
R410A
Februray 2018
Notes:
7KLVVHUYLFHPDQXDO
GHVFULEHVWHFKQLFDOGDWDRI
RXWGRRUXQLWDQGEUDQFKER[
$VIRULQGRRUXQLWVUHIHUWR
LWVVHUYLFHPDQXDO
5R+6FRPSOLDQWSURGXFWV
KDYH*!PDUNRQWKHVSHF
QDPHSODWH
[Model Name]
<Outdoor unit>
MXZ-4C36NAHZ
MXZ-5C42NAHZ
MXZ-8C48NAHZ
MXZ-8C48NA
MXZ-8C60NA
<Branch box>
PAC-MKA50BC
PAC-MKA30BC
PAC-MKA51BC
PAC-MKA31BC
PARTS CATALOG (OCB573)
[Service Ref.]
OUTDOOR UNIT: MXZ-4C36NAHZ
BRANCH BOX: PAC-MKA51BC
0RGHOQDPH
LQGLFDWLRQ
63/,77<3(+($73803$,5&21',7,21(56
5HYLVLRQ:
&RUUHFWHGWKHGHVFULSWLRQRI
RXWGRRUSRZHUFLUFXLWERDUG
LQSDJHDQGWKHPRGHO
VHOHFWLRQLQSDJHLQ
5(9,6('(',7,21(
6RPHGHVFULSWLRQVKDYH
EHHQPRGLILHG
2&+5(9,6('(',7,21'
LVYRLG

Other manuals for Mitsubishi Electric MXZ-5C42NAHZ

Questions and Answers:

Mitsubishi Electric MXZ-5C42NAHZ Specifications

General IconGeneral
SeriesMXZ
Cooling Capacity42, 000 BTU/h
Heating Capacity48, 000 BTU/h
Seasonal Energy Efficiency Ratio (SEER)20.0
RefrigerantR410A
Voltage208/230V
Phase1
Compressor TypeInverter
Maximum Number of Zones5
Operating Temperature (Heating)-13°F to 75°F
Indoor UnitsMulti-Zone Compatible
Operating Temperature (Cooling)14°F to 115°F

Summary

TECHNICAL CHANGES

SAFETY PRECAUTION

1-1. ALWAYS OBSERVE FOR SAFETY

General safety guidelines for operating and servicing air conditioners.

1-2. CAUTIONS RELATED TO NEW REFRIGERANT

Specific warnings for handling R410A refrigerant and related safety precautions.

OVERVIEW OF UNITS

2-1. CONSTRUCTION OF SYSTEM

Details the components and configuration of the air conditioning system.

2-2. SYSTEM OUTLINE

Provides a general description and diagrams of the system architecture.

2-3. TYPICAL COMBINATION EXAMPLE

Illustrates common ways indoor and outdoor units can be combined.

2-4. SIMPLIFIED PIPING SYSTEM

Explains the piping connections and sizes for different units.

SPECIFICATIONS

3-1. OUTDOOR UNIT SPECIFICATIONS

Technical specifications for outdoor units including capacity and dimensions.

3-2. BRANCH BOX SPECIFICATIONS

Technical specifications for branch boxes including connections and capacity.

DATA

4-1. SELECTION OF COOLING/HEATING UNITS

Guides for selecting appropriate indoor and outdoor units based on load.

4-2. CORRECTION BY TEMPERATURE

Provides correction curves for capacity based on temperature variations.

4-3. STANDARD OPERATION DATA

Lists operational data like ambient temperature and refrigerant amounts.

4-4. STANDARD CAPACITY DIAGRAM

Graphical representation of capacity ratios based on total indoor unit capacity.

4-4-1. MXZ-4C36NAHZ <cooling>

Cooling capacity ratio vs. total indoor unit capacity.

4-4-2. MXZ-4C36NAHZ <heating>

Heating capacity ratio vs. total indoor unit capacity.

4-4-3. MXZ-5C42NAHZ <cooling>

Cooling capacity ratio vs. total indoor unit capacity.

4-4-4. MXZ-5C42NAHZ <heating>

Heating capacity ratio vs. total indoor unit capacity.

4-4-5. MXZ-8C48NA MXZ-8C48NAHZ <cooling>

Cooling capacity ratio vs. total indoor unit capacity.

4-4-6. MXZ-8C48NA MXZ-8C48NAHZ <heating>

Heating capacity ratio vs. total indoor unit capacity.

4-4-7. MXZ-8C60NA <cooling>

Cooling capacity ratio vs. total indoor unit capacity.

4-4-8. MXZ-8C60NA <heating>

Heating capacity ratio vs. total indoor unit capacity.

4-5. CORRECTING CAPACITY FOR CHANGES IN THE LENGTH OF REFRIGERANT PIPING

Information on adjusting capacity based on piping length.

4-6. NOISE CRITERION CURVES

Noise levels of outdoor units at different frequencies.

OUTLINES AND DIMENSIONS

5-1. OUTDOOR UNIT

Dimensional drawings and installation space requirements for outdoor units.

5-2. BRANCH BOX

Dimensional drawings and installation details for branch boxes.

WIRING DIAGRAM

6-1. OUTDOOR UNIT

Electrical wiring diagrams for outdoor units.

6-2. BRANCH BOX

Electrical wiring diagrams for branch boxes.

NECESSARY CONDITIONS FOR SYSTEM CONSTRUCTION

7-1. TRANSMISSION SYSTEM SETUP

Guidelines for setting up the communication system between units.

7-2. REFRIGERANT SYSTEM DIAGRAM

Diagrams illustrating refrigerant flow in cooling and heating modes.

7-3. TYPICAL CONTROL SYSTEM

Explains the typical control system wiring and operation.

TROUBLESHOOTING

8-1. TROUBLESHOOTING

General guidance on identifying and resolving issues.

8-2. CHECK POINTS FOR TEST RUN

Pre-test run checks and procedures for various test run types.

8-3. SELF-DIAGNOSIS ACTION BY FLOWCHART

Flowcharts for diagnosing system errors based on check codes.

8-4. TROUBLESHOOTING BY INFERIOR PHENOMENA

Troubleshooting common operational problems and their causes.

8-5. OUTDOOR UNIT INPUT/OUTPUT CONNECTOR

Details on connector functions and wiring for outdoor units.

8-6. HOW TO CHECK THE PARTS

Procedures for checking the resistance and condition of various components.

8-7. HOW TO CHECK THE COMPONENTS

Thermistor characteristic graphs and resistance values for checking components.

8-8. TEST POINT DIAGRAM

Diagrams showing test points on circuit boards for diagnostics.

8-9. INTERNAL SWITCH FUNCTION TABLE

Explains the functions of internal switches on various units.

8-10. OUTDOOR UNIT FUNCTIONS

Lists and explains functions displayed on the unit's LED indicators.

8-11. BRANCH BOX UNIT OPERATION MONITOR FUNCTION

Details on using the service tool to monitor branch box operations.

8-12. SELECTING FUNCTIONS USING THE REMOTE CONTROLLER

How to set various functions using the remote controller.

PRECAUTIONS AGAINST REFRIGERANT LEAKAGE

9-1-1. Introduction

Importance of preventing refrigerant leaks and maximum concentration limits.

9-1-2. Confirming procedure of R410A concentration

Steps to calculate and confirm R410A concentration in rooms.

DISASSEMBLY PROCEDURE

10-1. OUTDOOR UNIT

Step-by-step instructions for disassembling outdoor units.

10-2. BRANCH BOX

Step-by-step instructions for disassembling branch boxes.

Related product manuals