Type | Multi-zone |
---|---|
Series | MXZ |
Cooling Capacity | 42, 000 BTU/h |
Heating Capacity | 48, 000 BTU/h |
Number of Zones | 5 |
Voltage | 208/230V |
Compressor Type | Inverter |
Refrigerant | R410A |
Operating Temperature (Cooling) | 14°F to 115°F |
Indoor Unit Dimensions (HxWxD) | Varies by indoor unit model |
Indoor Unit Weight | Varies by indoor unit model |
Indoor Unit Compatibility | Multiple indoor units available |
General safety measures to follow before and during repair work.
Specific safety warnings and handling instructions for R410A refrigerant.
Guidelines for safe and proper refrigerant piping installation and considerations.
Defines the operational temperature limits for cooling and heating.
Specifies maximum piping lengths and dimensions for refrigerant lines.
Function to energize compressor winding to prevent moisture issues.
Automatically detects and corrects improper wiring or piping.
Adjusts refrigerant evaporating temperature settings for specific conditions.
Safety precautions and initial checks before troubleshooting.
How to recall and interpret stored failure codes for diagnosis.
Step-by-step guide for diagnosing outdoor unit malfunctions.
Detailed table of symptoms, LED indications, conditions, and remedies.
Specifications and resistance values for checking key components.
Diagnostic flowcharts for specific operational issues.