Category | Air Conditioner |
---|---|
Cooling Capacity | 5.0 kW |
Energy Efficiency Ratio (EER) | 3.21 |
Power Supply | 220-240V, 50Hz |
Refrigerant | R32 |
Coefficient of Performance (COP) | 3.61 |
Indoor Unit Noise Level | 45 dB(A) |
Outdoor Unit Noise Level | 50 dB(A) |
Differentiates PUG (cooling) and PUGH (heat pump) models.
Details compatible indoor units for PUG and PUGH outdoor units.
Mentions high-efficiency scroll compressor and factory pre-charged refrigerant.
Provides specifications for PK Series AC systems.
Provides specifications for PKH Series heat pump systems.
Provides specifications for PC Series AC systems.
Provides specifications for PCH Series heat pump systems.
Provides specifications for PL Series AC systems.
Provides specifications for PLH Series heat pump systems.
Details electrical specs for PUG condensing units.
Details electrical specs for PUGH outdoor units.
Standard operating data for PK/PKH-FK indoor with PUG/PUGH outdoor units.
Standard operating data for PL/PLH indoor with PUG/PUGH outdoor units.
Standard operating data for PC/PCH indoor with PUG/PUGH outdoor units.
Cooling operating pressures for PK/H series units across various conditions.
Cooling operating pressures for PL/H series units across various conditions.
Cooling operating pressures for PC/H series units across various conditions.
Heating operating pressures for PKH series units.
Heating operating pressures for PLH series units.
Heating operating pressures for PCH series units.
Provides physical dimensions and required installation clearances for the unit.
Details the guaranteed voltage range for the unit's power supply.
Specifies indoor and outdoor operating temperature and humidity limits.
Provides refrigerant charge adjustment for KC compressors based on line length.
Provides refrigerant charge adjustment for K4/K3 compressors based on line length.
Factors to adjust cooling capacity based on refrigerant piping length.
Factors to adjust heating capacity based on refrigerant piping length.
Explains operation activation and P8 fault code detection logic.
Details the functions of safety switches, sensors, and motors on the control board.
Covers line voltage, timing delays, fault memory, and LED indicators.
Wiring diagrams for PUG units across various voltage/phase configurations.
Wiring diagrams for PUGH units across various voltage/phase configurations.
Illustrates the refrigerant piping for PUG models.
Illustrates the refrigerant piping for PUGH heat pump models.
Explains the purpose and usage of the unit's service ports.
Lists structural components for all PUG and PUGH models.
Lists functional components for PUG AKB and BKB models.
Lists functional components for PUGH AKB and BKB models.
Lists electrical panel components for PUG AKB and BKB models.
Lists electrical panel components for PUGH AKB and BKB models.