Mitsubishi Electric PUHY-P72 Specifications

General IconGeneral
ModelPUHY-P72
TypeHeat Pump
RefrigerantR410A
Outdoor Unit Noise Level58 dB(A)
SeriesP Series

Summary

MITSUBISHI ELECTRIC AIR CONDITIONER Service Handbook

Safety Precautions

General Precautions

General safety guidelines and precautions for installation, operation, and maintenance.

Transportation and Installation

Installation

Piping Work

Wiring Work

Relocation and Repairs

Additional Precautions

Chapter 1 Check Before Servicing

1-1 Preparation for Piping Work

Guidelines and steps for preparing piping work, including checking refrigerant type and tools.

1-1-2 Tool Preparation

List of tools and materials required for R410A systems, including those to use and avoid.

1-2 Handling and Characteristics of Piping Materials, Refrigerant, and Refrigerant Oil

Information on copper pipe materials, types, processing, and handling of refrigerants and oils.

1-3 Working with Refrigerant Piping

Detailed procedures for pipe brazing, air tightness testing, and vacuum drying.

1-4 Precautions for Wiring

Essential safety precautions and guidelines for electrical wiring work.

Chapter 2 Restrictions

2-1 System Configurations

Details on compatible indoor units and system capacity configurations.

2-2 Types and Maximum Allowable Length of Cables

Specifications for M-NET transmission lines and remote controller wiring, including length limits.

2-3 Switch Settings

Configuration of necessary switch settings based on system setup.

2-4 M-NET Address Settings

Table detailing M-NET address settings for various units and controllers.

2-5 Demand Control Overview

Explanation of demand control functions and how they are implemented via DIP SW6-8.

2-6 System Connection Example

Illustrations of typical system connections for MA, ME, and combined remote controller setups.

2-7 Example System with an MA Remote Controller

Wiring diagrams and cautions for single refrigerant systems with MA remote controllers.

2-8 Example System with an ME Remote Controller

Wiring diagrams and cautions for systems using ME remote controllers with system controllers.

2-9 Example System with an MA and an ME Remote Controller

Wiring diagrams and cautions for systems using both MA and ME remote controllers.

2-10 Restrictions on Refrigerant Pipes

Guidelines for refrigerant pipe length and size restrictions for various models.

Chapter 3 Major Components, Their Functions and Refrigerant Circuits

3-1 External Appearance and Refrigerant Circuit Components of Outdoor Unit

Visual identification of outdoor unit components and their arrangement.

3-1-2 Outdoor Unit Refrigerant Circuits

Diagrams illustrating the refrigerant circuits for various outdoor unit models.

3-3 Functions of the Major Components of Outdoor Unit

Detailed explanations of the functions, specifications, and check methods for outdoor unit components.

3-4 Functions of the Major Components of Indoor Unit

Explanation of the functions and specifications of indoor unit components.

Chapter 4 Electrical Components and Wiring Diagrams

4-1 Outdoor Unit Circuit Board Arrangement

Layout and identification of components within the outdoor unit's control box.

4-2 Outdoor Unit Circuit Board Components

Detailed breakdown of components on the Control, M-NET, INV, Fan, Noise Filter, and Connect boards.

4-3 Outdoor Unit Electrical Wiring Diagrams

Schematic diagrams illustrating the electrical connections for outdoor units.

4-4 Transmission Booster Electrical Wiring Diagrams

Wiring diagram for the transmission booster unit.

Chapter 5 Control

5-1 Dipswitch Functions and Factory Settings

Details on outdoor unit, indoor unit, and remote controller dipswitch functions and settings.

5-2 Outdoor Unit Control

Overview and explanation of various control methods for the outdoor unit.

5-3 Operation Flowcharts

Flowcharts illustrating operational sequences for indoor and outdoor units in different modes.

Chapter 6 Test Run

6-1 Read before Test Run

Essential checks and precautions to perform before conducting a test run.

6-2 MA and ME Remote Controller Functions and Specifications

Comparison of functions and specifications between MA and ME remote controllers.

6-3 Making the Group and Interlock Settings from an ME Remote Controller

Procedures for setting up group operations and interlocks using an ME remote controller.

6-4 Selecting Remote Controller Functions from an ME Remote Controller

Guide to selecting and changing functions on the ME remote controller.

6-5 Making Interlock Settings from an MA Remote Controller

Instructions for setting up LOSSNAY interlocks using an MA remote controller.

6-7 Test Run Method

Step-by-step guide for performing a test run using the MA remote controller.

6-8 Operation Characteristics and Refrigerant Charge

Understanding the operating characteristics and refrigerant charge importance.

6-9 Evaluating and Adjusting Refrigerant Charge

Methods for evaluating and adjusting refrigerant charge, including calculation formulas.

6-10 The Following Symptoms Are Normal

Description of normal operating symptoms that may occur.

6-11 Standard Operation Data (Reference Data)

Reference data for standard operating conditions of various models.

Chapter 7 Troubleshooting Using Error Codes

7-1 Error Code and Preliminary Error Code Lists

Comprehensive list of error codes and their preliminary details.

7-2 Error Code Definitions and Solutions: Codes [0 - 999]

Detailed definitions and solutions for error codes in the 0-999 range.

7-3 Error Code Definitions and Solutions: Codes [1000 - 1999]

Detailed definitions and solutions for error codes in the 1000-1999 range.

7-4 Error Code Definitions and Solutions: Codes [2000 - 2999]

Detailed definitions and solutions for error codes in the 2000-2999 range.

7-5 Error Codes [4000 - 4999]

Detailed definitions and solutions for error codes in the 4000-4999 range.

7-6 Error Code Definitions and Solutions: Codes [5000 - 5999]

Detailed definitions and solutions for error codes in the 5000-5999 range.

7-7 Error Code Definitions and Solutions: Codes [6000 - 6999]

Detailed definitions and solutions for error codes in the 6000-6999 range.

7-8 Error Code Definitions and Solutions: Codes [7000 - 7999]

Detailed definitions and solutions for error codes in the 7000-7999 range.

Chapter 8 Troubleshooting Based on Observed Symptoms

8-1 MA Remote Controller Problems

Troubleshooting steps for common issues with MA remote controllers.

8-2 ME remote Controller Problems

Troubleshooting steps for common issues with ME remote controllers.

8-3 Refrigerant Control Problems

Diagnosis and solutions for issues related to refrigerant control and capacity.

8-4 Checking Transmission Waveform and for Electrical Noise Interference

Methods for checking transmission waveforms and identifying electrical noise issues.

8-5 Pressure Sensor Circuit Configuration and Troubleshooting Pressure Sensor Problems

Configuration and troubleshooting for high and low-pressure sensors.

8-6 Troubleshooting Solenoid Valve Problems

Troubleshooting procedures for various solenoid valves.

8-7 Troubleshooting Outdoor Unit Fan Problems

Diagnosis and solutions for issues related to outdoor unit fans and their control.

8-8 Troubleshooting LEV Problems

Troubleshooting steps for linear expansion valves (LEV) in indoor and outdoor units.

8-9 Troubleshooting Inverter Problems (TLMU)

Comprehensive troubleshooting guide for inverter-related issues specific to TLMU models.

8-10 Troubleshooting Inverter Problems (YLMU)

Comprehensive troubleshooting guide for inverter-related issues specific to YLMU models.

8-11 Control Circuit (TLMU)

Explanation of control power supply function blocks for TLMU models.

8-12 Control Circuit (YLMU)

Explanation of control power supply function blocks for YLMU models.

8-13 Measures for Refrigerant Leakage

Procedures and precautions for detecting and repairing refrigerant leaks.

8-14 Compressor Replacement Instructions

Step-by-step instructions for removing and replacing the compressor.

8-15 Heat exchanger Replacement Instructions

Instructions for safely replacing the heat exchanger, considering material properties.

8-16 Troubleshooting Problems Using the LED Status Indicators on the Outdoor Unit

Guide to interpreting LED status indicators on the outdoor unit circuit board for troubleshooting.

Chapter 9 LED Status Indicators on the Outdoor Unit Circuit Board

9-1 LED Status Indicators

Overview of LED status indicators and how to read them.

9-1-1 How to Read the LED

Explanation on how to interpret numerical and flag displays from LEDs.

9-1-2 Initial LED Display

Information displayed on the monitor screen during initial settings.

9-2 LED Status Indicators Table

Comprehensive table mapping SW4 settings to LED status and display information.