48
2 EQUIPMENT SPECIFICATIONS
2.4 SSCNETIII Cables
Wiring process of SSCNETIII cable
Put the SSCNET cable in the duct or fix the cable at the closest part to the Motion CPU module with bundle material in order
to prevent SSCNET cable from putting its own weight on SSCNET connector.
Putting in the duct
When putting in a duct, leave space for installing the module.
Bundle fixing
Optical cord should be given loose slack to avoid from becoming smaller than the minimum bend radius, and it should not be
twisted. When bundling the cable, fix and hold it in position by using cushioning such as sponge or rubber which does not
contain migratable plasticizing. If using adhesive tape for bundling the cable, fire resistant acetate cloth adhesive tape 570F
(Teraoka Seisakusho Co., Ltd) is recommended.
Bundle material
Recommended product
NK clamp SP type (NIX,INC.)
Panel
Cable
Cord loose
slack
Motion CPU moduleBase unit