EasyManua.ls Logo

Mitsubishi Electric SLZ-KA50VAL User Manual

Mitsubishi Electric SLZ-KA50VAL
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
600o600
CEILING
CASSETTE
CEILING
CONCEALED
OUTDOOR
UNIT
B.1 600 o 600 CEILING CASETTE (SLZ) ....................................................B-3
Combination Table .........................................................................................B-2
SLZ-KA25VA
SLZ-KA25VAL
SLZ-KA35VA
SLZ-KA35VAL
SLZ-KA50VA
SLZ-KA50VAL
B.2 CEILING CONCEALED (SEZ) ................................................................B-39
SEZ-KD25VA
SEZ-KD25VAL
SEZ-KD35VA
SEZ-KD35VAL
SEZ-KD50VA
SEZ-KD50VAL
SEZ-KD60VA
SEZ-KD60VAL
SEZ-KD71VA
SEZ-KD71VAL
B.3 OUTDOOR UNIT (SUZ)..........................................................................B-85
SUZ-KA25VA
SUZ-KA35VA
SUZ-KA50VA
SUZ-KA60VA
SUZ-KA71VA
S series Model List

Other manuals for Mitsubishi Electric SLZ-KA50VAL

Questions and Answers:

Mitsubishi Electric SLZ-KA50VAL Specifications

General IconGeneral
TypeCeiling Cassette
Cooling Capacity5.0 kW
Outdoor Unit Dimensions (W x H x D)800 x 550 x 285 mm
RefrigerantR410A
Outdoor Unit Noise Level49 dB(A)
Power Supply220-240V, 50Hz
Indoor Unit Dimensions (W x H x D)570 x 570 mm
Indoor Unit Noise Level (Cooling)30 dB(A)

Summary

Combination Table

B.1 600x600 Ceiling Cassette (SLZ)

B.1.1 Specifications

Detailed technical data including capacity, input, and EEL rank for indoor and outdoor units.

B.1.2 Outlines and Dimensions

Physical dimensions, installation layouts, and component locations for the indoor unit.

B.1.3 Wiring Diagram

Electrical schematics for connecting the indoor unit and remote controllers.

B.1.4 Refrigerant System Diagram

Diagram illustrating the refrigerant flow and key components of the system.

B.1.5 Performance Data

Tables detailing cooling and heating performance under various conditions.

B.1.6 4-Way Airflow System

Information on fresh air intake and airflow system installation.

B.1.7 Noise Criteria Curves

Graphs showing sound pressure levels across different frequencies.

B.1.8 Outlet Air Speed and Coverage Range

Data on airflow speed and the distance air reaches.

B.1.9 Center of Gravity Position

Specifies the center of gravity for safe handling and installation.

B.1.10 Remote Controller

Details on operating the wireless and wired remote controllers.

B.1.11 Troubleshooting

Guidance on identifying and resolving common operational issues.

B.1.12 Installation Procedure

Step-by-step instructions for safe and correct installation.

B.2 Ceiling-Concealed (SEZ)

B.2.1 Specifications

Detailed technical data including capacity, input, and EEL rank for indoor units.

B.2.2 Outlines and Dimensions

Physical dimensions, installation layouts, and component locations for the indoor unit.

B.2.3 Wiring Diagram

Electrical schematics for connecting the indoor unit and remote controllers.

B.2.4 Refrigerant System Diagram

Diagram illustrating the refrigerant flow and key components of the system.

B.2.5 Performance Data

Tables detailing cooling and heating performance under various conditions.

B.2.6 Noise Criteria Curves

Graphs showing sound pressure levels across different frequencies.

B.2.7 Indoor Fan Performance and Corrected Air Flow

Graphs showing fan performance and airflow rates for indoor units.

B.2.8 Center of Gravity Position

Specifies the center of gravity for safe handling and installation.

B.2.9 Remote Controller

Details on operating the wireless and wired remote controllers.

B.2.10 Troubleshooting

Guidance on identifying and resolving common operational issues.

B.2.11 Installation Procedure

Step-by-step instructions for safe and correct installation.

B.3 Outdoor Unit (SUZ)

B.3.1 Outlines and Dimensions

Physical dimensions, required installation space, and component locations.

B.3.2 Wiring Diagram

Electrical schematics for connecting the outdoor unit's components.

B.3.3 Refrigerant System Diagram

Diagram illustrating the refrigerant flow and key components.

B.3.4 Performance Curves

Graphs showing capacity and input correction factors based on conditions.

B.3.5 Noise Criteria Curves

Graphs showing sound pressure levels across different frequencies.

B.3.6 Actuator Control

Details on how sensors and actuators interact during operation.

B.3.7 Troubleshooting

Guidance on identifying and resolving common operational issues.

B.3.8 Earthquake-proof Strength Analysis

Calculation and verification of anchor bolt strength for seismic resistance.

B.3.9 Capacity Correction Ratio Curve Piping Length

Curves showing how piping length affects capacity and input correction.

B.3.10 Installation Procedure

Step-by-step instructions for safe and correct outdoor unit installation.

Related product manuals