EasyManua.ls Logo

Mitsubishi Electric SLZ-KA25VA User Manual

Mitsubishi Electric SLZ-KA25VA
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
600o600
CEILING
CASSETTE
CEILING
CONCEALED
OUTDOOR
UNIT
B.1 600 o 600 CEILING CASETTE (SLZ) ....................................................B-3
Combination Table .........................................................................................B-2
SLZ-KA25VA
SLZ-KA25VAL
SLZ-KA35VA
SLZ-KA35VAL
SLZ-KA50VA
SLZ-KA50VAL
B.2 CEILING CONCEALED (SEZ) ................................................................B-39
SEZ-KD25VA
SEZ-KD25VAL
SEZ-KD35VA
SEZ-KD35VAL
SEZ-KD50VA
SEZ-KD50VAL
SEZ-KD60VA
SEZ-KD60VAL
SEZ-KD71VA
SEZ-KD71VAL
B.3 OUTDOOR UNIT (SUZ)..........................................................................B-85
SUZ-KA25VA
SUZ-KA35VA
SUZ-KA50VA
SUZ-KA60VA
SUZ-KA71VA
S series Model List

Other manuals for Mitsubishi Electric SLZ-KA25VA

Questions and Answers:

Mitsubishi Electric SLZ-KA25VA Specifications

General IconGeneral
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
Power Supply220-240 V, 50 Hz
Indoor Unit Weight9.5 kg
Outdoor Unit Dimensions (HxWxD)550 x 800 x 285 mm
Outdoor Unit Weight35 kg
RefrigerantR32
Outdoor Unit Dimensions (W x H x D)800 x 550 x 285 mm
Energy Efficiency Ratio (EER)3.5
Energy Efficiency Ratio (Cooling)3.5
Noise Level (Outdoor Unit)50 dB(A)

Summary

B.1 600 x 600 CEILING CASSETTE (SLZ)

B.1.1 SPECIFICATIONS

Technical specifications for the SLZ series ceiling cassette indoor units.

B.1.2 OUTLINES AND DIMENSIONS

Physical dimensions and outline drawings for SLZ series indoor units and remote controllers.

B.1.3 WIRING DIAGRAM

Wiring diagram for the SLZ series ceiling cassette indoor units.

B.1.4 REFRIGERANT SYSTEM DIAGRAM

Diagram illustrating the refrigerant system for the SLZ series.

B.1.5 PERFORMANCE DATA

Performance data tables for the SLZ series ceiling cassette units.

B.1.6 4-WAY AIR FLOW SYSTEM

Information on the 4-way airflow system of the SLZ series units.

B.1.7 NOISE CRITERIA CURVES

Noise criteria curves for the SLZ series indoor units.

B.1.8 OUTLET AIR SPEED AND COVERAGE RANGE

Data on outlet air speed and coverage range for the SLZ series.

B.1.9 CENTER OF GRAVITY POSITION

Information on the center of gravity position for the SLZ series.

B.1.10 REMOTE CONTROLLER

Details about the remote controllers for the SLZ series.

B.1.11 TROUBLESHOOTING

Troubleshooting guide for common issues with the SLZ series units.

B.1.12 INSTALLATION PROCEDURE

Step-by-step instructions for installing the SLZ series units.

B.1.2.1 INDOOR UNIT

Outline and dimensions for the SLZ series indoor units.

B.1.2.2 WIRELESS REMOTE CONTROLLER

Outline and dimensions for the SLZ series wireless remote controller.

B.1.2.3 WIRED REMOTE CONTROLLER

Outline and dimensions for the SLZ series wired remote controller.

B.2 CEILING CONCEALED (SEZ)

B.2.1 SPECIFICATIONS

Technical specifications for the SEZ series ceiling concealed indoor units.

B.2.2 OUTLINES AND DIMENSIONS

Physical dimensions and outline drawings for SEZ series indoor units and remote controllers.

B.2.3 WIRING DIAGRAM

Wiring diagram for the SEZ series ceiling concealed indoor units.

B.2.4 REFRIGERANT SYSTEM DIAGRAM

Diagram illustrating the refrigerant system for the SEZ series.

B.2.5 PERFORMANCE DATA

Performance data tables for the SEZ series ceiling concealed units.

B.2.6 NOISE CRITERIA CURVES

Noise criteria curves for the SEZ series indoor units.

B.2.7 INDOOR FAN PERFORMANCE AND CORRECTED AIR FLOW

Indoor fan performance and corrected airflow data for SEZ series.

B.2.8 CENTER OF GRAVITY POSITION

Information on the center of gravity position for the SEZ series.

B.2.9 REMOTE CONTROLLER

Details about the remote controllers for the SEZ series.

B.2.10 TROUBLESHOOTING

Troubleshooting guide for common issues with the SEZ series units.

B.2.11 INSTALLATION PROCEDURE

Step-by-step instructions for installing the SEZ series units.

B.2.2.1 INDOOR UNIT

Outline and dimensions for the SEZ series indoor units.

B.2.2.2 WIRED REMOTE CONTROLLER

Outline and dimensions for the SEZ series wired remote controller.

B.2.2.3 WIRELESS REMOTE CONTROLLER

Outline and dimensions for the SEZ series wireless remote controller.

B.3 OUTDOOR UNIT (SUZ)

B.3.1 OUTLINES AND DIMENSIONS

Outline and dimension drawings for SUZ series outdoor units.

B.3.2 WIRING DIAGRAM

Wiring diagram for the SUZ series outdoor units.

B.3.3 REFRIGERANT SYSTEM DIAGRAM

Diagram illustrating the refrigerant system for SUZ series outdoor units.

B.3.4 PERFORMANCE CURVES

Performance curves for SUZ series outdoor units.

B.3.5 NOISE CRITERIA CURVES

Noise criteria curves for SUZ series outdoor units.

B.3.6 ACTUATOR CONTROL

Information on actuator control for SUZ series outdoor units.

B.3.7 TROUBLESHOOTING

Troubleshooting guide for common issues with SUZ series outdoor units.

B.3.8 EARTHQUAKE-PROOF STRENGTH ANALYSIS

Analysis of earthquake-proof strength for SUZ series outdoor units.

B.3.9 CAPACITY CORRECTION RATIO CURVE PIPING LENGTH

Correction ratio curves based on refrigerant piping length for SUZ series.

B.3.10 INSTALLATION PROCEDURE

Step-by-step instructions for installing SUZ series outdoor units.

Related product manuals