3. Operation
3.5.2 Vane·Vent. (Lossnay)
<Accessing the menu>
MENU
ON
OFF
RETURN
SELECT
HOLD
Main Main menu
Operation
MENU
ON
OFF
RETURN
SELECT
HOLD
Main menu: RETURN
Cursor
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Select “Operation” from the Main
menu (refer to page 7), and press
the [SELECT/HOLD] button.
Select “Vane·Louver·Vent.
(Lossnay)” from the Operation
menu, and press the [SELECT/
HOLD] button.
<To Change the Airflow’s Up/Down Direction> (for IR wireless
remote controller)
With the unit running, press the Airflow Up/Down button 5 as necessary.
Each press changes the direction. The current direction is shown at
display.
Note:
●
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in “STAND BY” or “DEFROST” states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the temper-
ature setting.
<[Manual] To Change the Airflow’s Left/Right Direction>
* The louver button cannot be used.
Stop the unit operation, hold the lever of the louver,
and adjust to the desired direction.
* Do not set to the inside direction when the unit is in
the cooling or drying mode because there is a risk
of condensation and water dripping.
Caution:
To prevent falls, maintain a stable footing when operating the unit.
<Vane setting>
Press the [F1] or [F2] button to go
through the vane setting options:
“Auto”, “Step 1”, “Step 2”, “Step 3”,
“Step 4”, “Step 5” and “Swing”.
Select the desired setting.
Auto
Swing
Auto
Step 3
Swing
Step 1
Step 4
Step 2
Step 5
Select “Swing” to move the vanes
up and down automatically.
When set to “Step 1” through “Step
5”, the vane will be xed at the se-
lected angle.
under the vane setting icon
This icon will appear when the vane
is set to “Step 5” and the fan oper-
ates at low speed during cooling or
drying operation (depends on the
model).
The icon will go off in an hour, and
the vane setting will automatically
change.
<Ventilation setting>
Fri
Low
Vent.
MENU
ON
OFF
RETURN
SELECT
HOLD
Press the [F3] button to go through
the ventilation setting options in the
order of “Off”, “Low”, and “High”.
* Settable only when Lossnay unit is
connected.
Off Low High
Off Low High
The fan on some models of indoor
units may be interlocked with cer-
tain models of ventilation units.
<Returning to the Operation menu>
MENU
ON
OFF
RETURN
SELECT
HOLD
Main menu: RETURN
Cursor
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Press the [RETURN] button to go
back to the Operation menu.
83
83
Fri
Room
Set temp.
Mode Temp. Fan
Cool Auto
MENU
ON
OFF
RETURN
SELECT
HOLD
Fri
Off
Vent.Vane
Swing
(Sample screen on CITY MULTI)
VG79Y108H01_en.indd 8 2019/08/07 9:36:20
009

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric Trane TPCA0A 1KA70 Series and is the answer not in the manual?

Mitsubishi Electric Trane TPCA0A 1KA70 Series Specifications

General IconGeneral
BrandMitsubishi Electric
ModelTrane TPCA0A 1KA70 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals