EasyManua.ls Logo

Mitsubishi Heavy Industries FDT71KXE6 User Manual

Mitsubishi Heavy Industries FDT71KXE6
394 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INVERTER DRIVEN MULTI-INDOOR UNIT
CLIMATE CONTROL SYSTEM
Alternative refrigerant R410A use models
(OUTDOOR UNIT)
Manual No. '08
KX-T-117
KX6 series
FDC112KXEN6, 140KXEN6, 155KXEN6 (1 phase)
FDC112KXES6, 140KXES6, 155KXES6 (3 phase)
FDT28KXE6
36KXE6
45KXE6
56KXE6
71KXE6
90KXE6
112KXE6
140KXE6
160KXE6
FDUM22KXE6
28KXE6
36KXE6
45KXE6
56KXE6
71KXE6
90KXE6
112KXE6
140KXE6
FDTC22KXE6
28KXE6
36KXE6
45KXE6
56KXE6
FDQS22KXE6
28KXE6
36KXE6
45KXE6
56KXE6
FDU71KXE6
90KXE6
112KXE6
140KXE6
FDFU28KXE6
45KXE6
56KXE6
71KXE6
FDTW28KXE6
45KXE6
56KXE6
71KXE6
90KXE6
112KXE6
140KXE6
FDK22KXE6
28KXE6
36KXE6
45KXE6
56KXE6
FDTQ22KXE6
28KXE6
36KXE6
FDFL28KXE6
45KXE6
71KXE6
FDTS45KXE6
71KXE6
FDE36KXE6
45KXE6
56KXE6
71KXE6
112KXE6
140KXE6
(INDOOR UNIT)
-
KX6 series
-
(Heat pump type)
INVERTER DRIVEN MULTI-INDOOR-UNIT
CLIMATE CONTROL SYSTEM
Air-Conditioning & Refrigeration Systems Headquarters
16-5, 2-chome, Kounan, Minato-ku, Tokyo, 108-8215, Japan
Fax : (03) 6716-5926
No.106(0.55A) R

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries FDT71KXE6 and is the answer not in the manual?

Mitsubishi Heavy Industries FDT71KXE6 Specifications

General IconGeneral
Cooling Capacity7.1 kW
Heating Capacity8.0 kW
Power Supply220-240 V, 50 Hz
Net Weight (Outdoor Unit)32 kg
Net Weight (Indoor Unit)14 kg
Dimensions (Outdoor Unit)550 × 780 × 285 mm
Dimensions (Indoor Unit)290 x 1100 x 235 mm

Summary

GENERAL INFORMATION

Specific features

Details on the specific features of the KX6 Ultra Compact series, including high efficiency and compact design.

OUTDOOR UNIT

Electrical wiring

Wiring diagrams and explanations for models FDC112KXEN6, 140KXEN6, and 155KXEN6.

INDOOR UNIT

Specifications

Detailed specifications for various indoor unit types including Ceiling cassette, Duct connected, Wall mounted, and Floor standing.

COMMON INFORMATION

Operation chart

Details on the operating characteristics of outdoor units for 1-phase and 3-phase systems.

APPLICATION DATA

SAFETY PRECAUTIONS

Important safety precautions for installation, including WARNING and CAUTION points.

Cautions for servicing

Cautions for servicing (for R410A and compatible machines)

Important cautions for servicing, including refrigerant handling and tool usage.

Operation control function by the outdoor controller

Defrost (Defrost control)

Conditions and procedures for defrosting operation, including start and end criteria.

Protective control

Details on various protective controls for compressor and fan based on operating parameters.

Emergency stop control

Procedure for stopping all indoor units connected to the outdoor unit in an emergency.

System troubleshooting procedure

Basics of troubleshooting

Fundamental steps for troubleshooting, including data analysis and initial checks.

Contents of troubleshooting

A list of inspection displays (error codes) with corresponding names of inspection and classification.

Related product manuals