EasyManua.ls Logo

Mitsubishi Heavy Industries FDU250VSVD User Manual

Mitsubishi Heavy Industries FDU250VSVD
296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
STANDARD INVERTER PACKAGED AIR-CONDITIONERS
V Multi System
(Split system, Air to air heat pump type)
Manual No. '10 PAC-DB-142
DATA BOOK
CEILING CASSETTE-4 WAY COMPACT TYPE
Single type
FDTC40ZIXVD
50ZIXVD
60ZIXVD
Triple type
FDTC140VNTVD
140VSTVD
Single type
FDT40ZIXVD
50ZIXVD
60ZIXVD
71VNVD
100VNVD
100VSVD
125VNVD
125VSVD
140VNVD
140VSVD
Triple type
FDT140VNTVD
140VSTVD
200VSTVD
Single type
FDEN40ZIXVD
50ZIXVD
60ZIXVD
71VNVD
100VNVD
100VSVD
125VNVD
125VSVD
140VNVD
140VSVD
Triple type
FDEN140VNTVD
140VSTVD
200VSTVD
Twin type
FDEN71VNPVD
100VNPVD
100VSPVD
125VNPVD
125VSPVD
140VNPVD
140VSPVD
200VSPVD
250VSPVD
CEILING CASSETTE-4 WAY TYPE
DUCT CONNECTED-LOW/MIDDLE STATIC PRESSURE TYPE
CEILING SUSPENDED TYPE
Single type
FDUM50ZIXVD
60ZIXVD
71VNVD
100VNVD
100VSVD
125VNVD
125VSVD
140VNVD
140VSVD
Triple type
FDUM140VNTVD
140VSTVD
200VSTVD
DUCT CONNECTED-HIGH STATIC PRESSURE TYPE
Single type
FDU71VNVD
100VNVD
100VSVD
125VNVD
125VSVD
Twin type
FDUM100VNPVD
100VSPVD
125VNPVD
125VSPVD
140VNPVD
140VSPVD
200VSPVD
250VSPVD
Twin type
FDT71VNPVD
100VNPVD
100VSPVD
125VNPVD
125VSPVD
140VNPVD
140VSPVD
200VSPVD
250VSPVD
Double Twin type
FDT200VSDVD
250VSDVD
Twin type
FDTC71VNPVD
100VNPVD
100VSPVD
125VNPVD
125VSPVD
Double Twin type
FDTC200VSDVD
FDTC250VSDVD
FDU140VNVD
140VSVD
200VSVD
250VSVD
(OUTDOOR UNIT)
FDC71VN
100VN
100VS
125VN
125VS
FDC140VN
140VS
200VS
250VS
(INDOOR UNIT)
FDT40VD
50VD
60VD
71VD
100VD
125VD
FDEN40VD
50VD
60VD
71VD
100VD
125VD
Ragarding the Service Manual please see the Manual No.’10 • PAC-SM-143.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries FDU250VSVD and is the answer not in the manual?

Mitsubishi Heavy Industries FDU250VSVD Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelFDU250VSVD
CategoryAir Conditioner
LanguageEnglish

Summary

1. STANDARD INVERTER PACKAGED AIR-CONDITIONERS

1.1 SPECIFICATIONS

Detailed technical specifications for various air conditioning unit types, including electrical, mechanical, and operational data.

1.2 EXTERIOR DIMENSIONS

Provides dimensional drawings and specifications for indoor and outdoor units, including mounting and clearance requirements.

1.3 ELECTRICAL WIRING

Details electrical wiring diagrams and connection procedures for indoor and outdoor units, including safety precautions.

1.4 NOISE LEVEL

Presents sound pressure level data for various indoor and outdoor units across different frequency bands and operating modes.

1.5 CHARACTERISTICS OF FAN

Presents fan characteristic curves, showing the relationship between static pressure and airflow for different models and settings.

1.6 TEMPERATURE AND VELOCITY DISTRIBUTION

Illustrates airflow patterns and temperature distribution from indoor units under cooling and heating conditions.

1.7 PIPING SYSTEM

Diagrams illustrating the refrigerant piping layout for single, twin, triple, and double-twin type systems.

1.8 RANGE OF USAGE & LIMITATIONS

Outlines the operational temperature range and installation limitations for the air conditioning units.

1.9 SELECTION CHART

Provides tables and guidelines for selecting appropriate models and components based on capacity and system requirements.

1.10 APPLICATION DATA

Contains essential data for application and installation, including indoor unit installation, remote controller, outdoor unit, and wiring.

2. V MULTI SYSTEM

2.1 GENERAL INFORMATION

Provides general information about the V Multi system, including how to read model names and tables.

2.1.2 Table of models

Lists available models for ceiling cassette and suspended indoor units with corresponding outdoor unit capacities.

2.1.3 Table of system combinations

Details valid system combinations of outdoor and indoor units, including required branch pipe sets.

2.2 SPECIFICATIONS

Presents specifications for V Multi system indoor units, outdoor units, and operation charts.

2.3 EXTERIOR DIMENSIONS

Provides exterior dimensions for V Multi system indoor units, outdoor units, and remote controllers.

2.4 ELECTRICAL WIRING

Details electrical wiring diagrams for V Multi system indoor and outdoor units.

2.5 NOISE LEVEL

Provides noise level data for V Multi system indoor and outdoor units across different frequency bands.

2.6 TEMPERATURE AND VELOCITY DISTRIBUTION

Illustrates airflow patterns and temperature distribution for V Multi system indoor units.

2.7 PIPING SYSTEM

Diagrams showing the refrigerant piping system for V Multi system configurations.

2.8 RANGE OF USAGE & LIMITATIONS

Outlines the operating temperature range and limitations for V Multi systems.

2.9 SELECTION CHART

Provides guidance and charts for selecting appropriate V Multi system configurations based on capacity.

2.10 APPLICATION DATA

Contains application data including installation procedures for indoor units, remote controllers, and outdoor units.

3. OPTION PARTS

3.1 WIRELESS KIT

Details the wireless remote controller kit, including installation and setup procedures for various series.

3.1.2 FDT Series (RCN-T-36W-E)

Installation manual for the RCN-T-36W-E wireless remote controller for FDT series units.

3.1.3 FDEN Series (RCN-E1R)

Installation manual for the RCN-E1R wireless remote controller for FDEN series units.

3.1.4 FDUM,FDU Series (RCN-KIT3-E)

Installation manual for the RCN-KIT3-E wireless remote controller for FDUM and FDU series units.

3.2 SIMPLE WIRED REMOTE CONROLLER (RCH-E3)

Information on the simple wired remote controller (RCH-E3), including names and functions of sections.

3.3 FAN CONTROLLERT KIT (U-FCRA)

Instructions for installing the optional fan controller kit (U-FCRA) for high static pressure ducts.

3.4 BASE HEATER KIT (CW-H-E)

Installation manual for the base heater kit (CW-H-E) for outdoor units in low-temperature areas.

Related product manuals