Mitsubishi Heavy Industries FDU280KXZE1 User Manual

Mitsubishi Heavy Industries FDU280KXZE1
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL MANUAL
Manual No.'19 • KX-T-310D
Note:
(INDOOR UNIT)
VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS
Duct connected-High
static pressure type
compact type
Ceiling cassette-4 way type
FDT28KXZE1
36KXZE1
45KXZE1
56KXZE1
71KXZE1
90KXZE1
112KXZE1
140KXZE1
160KXZE1
Wall mounted type
FDK15KXZE1
22KXZE1
28KXZE1
36KXZE1
45KXZE1
56KXZE1
71KXZE1
90KXZE1
FDE36KXZE1
45KXZE1
56KXZE1
71KXZE1
112KXZE1
140KXZE1
Ceiling cassette-4 way
FDTC15KXZE1
22KXZE1
28KXZE1
36KXZE1
45KXZE1
56KXZE1
Ceiling cassette-2 way type
FDTW28KXE6F
45KXE6F
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
Ceiling cassette-1 way type
FDTS45KXE6F
71KXE6F
Ceiling suspended type
FDU650FKXZE1
1100FKXZE1
1800FKXZE1
2400FKXZE1
Outdoor air processing unit
FDU45KXE6F
Duct connected (thin)-Low
static pressure type
FDUT71KXE6F-E
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
160KXE6F
224KXZE1
280KXZE1
Duct connected-Low/Middle
static pressure type
FDUM22KXE6F
28KXE6F
36KXE6F
45KXE6F
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
160KXE6F
(1) This document describes the indoor units with service code /F (with motion sensor system
function).
DRAFT
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries FDU280KXZE1 and is the answer not in the manual?

Mitsubishi Heavy Industries FDU280KXZE1 Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelFDU280KXZE1
CategoryAir Conditioner
LanguageEnglish

Summary

VRF Inverter Air Conditioner Specifications

Ceiling Cassette-4 Way Type (FDT) Specifications

Detailed specifications for FDT series ceiling cassette indoor units, including cooling/heating capacities and power requirements.

Ceiling Cassette-4 Way Compact Type (FDTC) Specifications

Specifications for FDTC series ceiling cassette indoor units, covering capacities, power, and dimensions.

Ceiling Cassette-2 Way Type (FDTW) Specifications

Technical specifications for FDTW series 2-way ceiling cassette indoor units, including capacity and power data.

Ceiling Cassette-1 Way Type (FDTS) Specifications

Specifications for FDTS series 1-way ceiling cassette indoor units, detailing performance and physical attributes.

Duct Connected-High Static Pressure Type (FDU) Specifications

Technical data for FDU series indoor units with high static pressure, including capacities and operational details.

Duct Connected-Low/Middle Static Pressure Type (FDUM) Specifications

Specifications for FDUM series indoor units with low/middle static pressure, covering performance and installation data.

Duct Connected (Thin)-Low Static Pressure Type (FDUT) Specifications

Specifications for FDUT series thin duct indoor units, detailing capacities, power, and physical dimensions.

Wall Mounted Type (FDK) Specifications

Technical specifications for FDK series wall-mounted indoor units, including capacity, noise, and electrical data.

Ceiling Suspended Type (FDE) Specifications

Specifications for FDE series ceiling suspended indoor units, covering performance, dimensions, and electrical details.

Outdoor Air Processing Unit (FDU-F) Specifications

Specifications for FDU-F series outdoor air processing units, including capacity, power, and operational data.

Exterior Dimensions

Indoor Unit Exterior Dimensions

Provides general exterior dimensions and installation space requirements for indoor units.

Electrical Wiring

Ceiling Cassette-4 Way Type (FDT) Electrical Wiring

Electrical wiring schematic for FDT series ceiling cassette indoor units, illustrating component connections.

Noise Level

Ceiling Cassette-4 Way (FDT) Noise Level

Noise level data (sound pressure and power) for FDT series units across various operating conditions.

Ceiling Cassette-4 Way Compact Type (FDTC) Noise Level

Noise level specifications for FDTC series compact units, presented in octave band frequency.

Ceiling Cassette-2 Way Type (FDTW) Noise Level

Noise level data for FDTW series 2-way units, detailing sound pressure levels at different frequencies.

Ceiling Cassette-1 Way Type (FDTS) Noise Level

Noise level specifications for FDTS series 1-way units, showing sound pressure levels by octave band.

Duct Connected-High Static Pressure Type (FDU) Noise Level

Noise level data for FDU series high static pressure duct units, measured according to JIS B 8616.

Duct Connected-Low/Middle Static Pressure Type (FDUM) Noise Level

Noise level specifications for FDUM series duct units with low/middle static pressure.

Duct Connected (Thin)-Low Static Pressure Type (FDUT) Noise Level

Noise level data for FDUT series thin duct indoor units, including measurements at different frequencies.

Wall Mounted Type (FDK) Noise Level

Noise level specifications for FDK series wall-mounted units, detailing sound pressure levels by octave band.

Ceiling Suspended Type (FDE) Noise Level

Noise level data for FDE series ceiling suspended units, presented with octave band frequency analysis.

Outdoor Air Processing Unit (FDU-F) Noise Level

Noise level specifications for FDU-F outdoor air processing units, providing power level data.

Capacity Tables

Ceiling Cassette-4 Way Type (FDT) Capacity Tables

Cooling and heating capacity tables for FDT series indoor units across various indoor/outdoor air conditions.

Option Parts

Motion Sensor Kit Installation and Settings

Instructions for installing and setting the motion sensor kit, including precautions and detectable area.