Do you have a question about the Mitsubishi Heavy Industries SRC20ZGX-S and is the answer not in the manual?
Type | Split System |
---|---|
Cooling Capacity | 2.0 kW |
Heating Capacity | 2.5 kW |
Refrigerant | R32 |
Power Supply | 220-240V, 50Hz |
Outdoor Unit Dimensions (W x H x D) | 780 x 540 x 290 mm |
Noise Level (Indoor) | 21 dB(A) |
Details the inverter, fuzzy control, remote control flap/louver, and self-diagnosis functions.
Explains the meaning of characters in the model name for identification.
Lists technical specifications like capacity, power, dimensions, and components for SRK20ZGX-S.
Defines the operational limits for indoor/outdoor temperatures and piping length.
Provides diagrams and measurements for the indoor unit's exterior dimensions.
Illustrates the refrigerant piping system for different models, showing component flow.
Provides charts and examples for correcting cooling/heating capacity based on conditions.
Explains how to use the remote control buttons for various operations and modes.
Describes the function of the physical ON/OFF button on the unit for basic operation.
Explains the feature that resumes operation after a power interruption.
Details modifications for indoor unit PCB and remote control for dual remote setups.
Explains how to adjust flap and louver positions using the remote control.
Covers the comfortable timer, sleep timer, and off timer functions for scheduled operation.
Describes major component operations and control details during heating mode.
Describes major component operations and control details during cooling mode.
Explains how the unit determines and switches between operation modes based on temperature.
Details various protective functions like frost prevention, overload, and sensor errors.
Provides guidelines for selecting optimal installation locations for indoor and outdoor units.
Covers mounting the installation board, drilling holes, and fixing the indoor unit.
Details requirements for installing the outdoor unit on a firm base and securing it.
Explains preparation, connection, and sealing of refrigerant piping between units.
Outlines the procedure for conducting a trial run and checking for leaks.
Provides guidelines on the placement and usage of the wireless remote control.
Provides a flowchart and steps for diagnosing and resolving electrical equipment issues.
Introduces R410A refrigerant, its adoption, and chemical/pressure characteristics.
Covers piping materials, joints, processing, and brazing techniques for R410A.
Details tools for R410A, installation work, removal, and unit replacement procedures.
Explains procedures, checks, and accessories for recovering refrigerant safely.