Patricia DoyleSep 6, 2025
Why does the RUN light stay on after stopping my Mitsubishi Heavy Industries SRK50ZJ-S?
- VVictoria SmithSep 6, 2025
The RUN light illuminates during CLEAN operation. The run light turns off when the CLEAN operation ends.
Why does the RUN light stay on after stopping my Mitsubishi Heavy Industries SRK50ZJ-S?
The RUN light illuminates during CLEAN operation. The run light turns off when the CLEAN operation ends.
Why doesn't my Mitsubishi Heavy Industries Air Conditioner restart immediately after being stopped?
The Mitsubishi Heavy Industries Air Conditioner has a built-in delay. Restart is blocked for 3 minutes after you stop it to protect the unit. Please wait for three minutes before restarting.
Why does my Mitsubishi Heavy Industries Air Conditioner blow cold air during heating?
When the outdoor temperature is low and humidity is high, your Mitsubishi Heavy Industries Air Conditioner may automatically defrost. Please wait for the defrosting cycle to complete.
What is the slight gurgling sound from my Mitsubishi Heavy Industries SRK50ZJ-S Air Conditioner?
This sound is caused by refrigerating liquid moving within the Mitsubishi Heavy Industries Air Conditioner unit.
Why is steam escaping from my Mitsubishi Heavy Industries SRK50ZJ-S during COOL operation?
This may occur with your Mitsubishi Heavy Industries Air Conditioner if the room's temperature and humidity are very high. It disappears as soon as the temperature and humidity decrease.
What causes the slight cracking sound in my Mitsubishi Heavy Industries SRK50ZJ-S?
This slight cracking sound from your Mitsubishi Heavy Industries Air Conditioner is caused by heat expansion or contraction.
Type | Split System |
---|---|
Cooling Capacity | 5.0 kW |
Heating Capacity | 5.8 kW |
Energy Efficiency Ratio (EER) | 3.21 |
Coefficient of Performance (COP) | 3.61 |
Energy Efficiency Rating (Cooling) | A++ |
Power Supply | 220-240V, 50Hz |
Outdoor Noise Level | 50 dB(A) |
Indoor Noise Level | 28 dB(A) |