Do you have a question about the Mitsubishi Heavy Industries SRK71CF-BP and is the answer not in the manual?
Brand | Mitsubishi Heavy Industries |
---|---|
Model | SRK71CF-BP |
Category | Air Conditioner |
Language | English |
Details unit functionalities like flap/louver control and self-diagnosis.
Explanation of how to interpret model designations for series and specifications.
Detailed technical specifications for various SRK/SRC models.
Defines operational limits for indoor/outdoor temperatures and piping.
Details dimensions of indoor and outdoor units, including mounting space.
Illustrates refrigerant piping for different model series.
Graphs and tables for adjusting cooling capacity based on temperature and piping length.
Wiring diagrams for indoor and outdoor units, showing component connections.
Explains wireless and wired remote control functions for operation and indications.
Instructions for operating the unit using the indoor unit's ON/OFF button.
Explains the function that resumes operation after a power outage.
Steps to modify indoor unit PCB and remote control for custom cord switching.
Covers swing flap, swing louver, multi-directional airflow, and memory flap functions.
Details on how the comfortable timer adjusts start time based on room temperature.
Describes temperature control patterns during sleep timer operation.
Covers component operation, fan speeds, thermostat, HIGH POWER, and ECONOMY modes.
Defines operation blocks, startup, DRY cycles, and ECONOMY mode in dehumidifying.
Unit determines mode and correction values based on temperatures; handles restarts and mode changes.
Modifying PCB to lower range and adjusting settings via remote signals.
Fan speed settings for components and HIGH POWER mode operation.
How outdoor fan speed changes based on outdoor air temperature.
Component behavior during complete and thermostat-based stops.
External control outputs and input signal control via wired remote.
Controls mode switching using jumper wire J3 and CnT input.
Covers frost prevention, dew condensation, fan motor, compressor, and unit abnormality protections.
Compressor control based on outdoor heat exchanger temperature.
Protection against errors in signals between indoor and outdoor units.
Error indications for various sensor disconnections.
Table listing jumper settings, functions, and reference pages.
Essential safety warnings and precautions for installation and operation.
Guidelines for selecting appropriate indoor and outdoor unit locations.
Specifies maximum piping length and vertical height difference.
Covers board fixing, hole drilling, sleeve installation, wiring, and piping preparation.
Guidelines for stable installation of the outdoor unit.
Covers preparation, connection, air purge, and insulation of refrigerant piping.
Covers trial run steps, customer explanation, drain check, and standard operation data.
Covers valid distances, angles, and wall-mounting procedures for wireless remote.
Details PCB modification, location selection, and installation procedures for wired remote.
Covers exposed and recessed fitting methods for installation.
Covers default settings and the method to change functions via wired remote.
How to adjust the upper and lower temperature limits via the remote control.
Explains functions and shows wiring diagram for the SC-AD-ER.
Step-by-step troubleshooting for electrical issues.
Safety precautions before working on electrical equipment.
Initial checks to perform before starting troubleshooting.
Flowcharts for diagnosing and resolving unit not running or running with issues.
Covers self-diagnosis table, sensor error, and fan motor error inspection procedures.
Steps to check the indoor unit's circuit board and fan motor.
Procedures for evacuating the system and charging refrigerant.
Steps to troubleshoot and verify the remote control functionality.