Loading...
'17 • KX-T-264
Error code
Remote control:
LED Green Red
Indoor
Outdoor
Content
WAIT
WAIT
(2)
Keeps ashing
Stays OFF
Keeps ashing Keeps ashing
1. Applicable model
5. Troubleshooting
FDC224, 280KXZPE1 only
(In case of fuse blown, how
to check the unit before
replacement of fuse.)
Diagnosis Countermeasure
YES
YES
NO
NO
YES
NO
Isn't
there any short circuit
between phases of noise
filter?
Isn't
there any crack or damage
on power transistor
module or diode stack?
Isn't
there any anomaly on
reactor?
Replace noise filter
Replace reactor
Replace inverter PCB
Replace fuse.
2. Error detection method
3
.
Condition of error displayed
4. Presumable cause
Fuse blown
Noise filter anomaly
Anomalous connection of
wire between PCBs
Indoor unit control PCB
anomaly
Remote control anomaly
Breakage of connecting wires
of remote control
Outdoor unit control PCB
anomaly
Note: