'22 • PAC-SM-412
-
16
-
(c) Operation check mode
Thereisnocommunicationwiththeoutdoorunitbutitallowsperformingoperationinrespectivemodesbyoperating
the remote control.
(d)Drainpumptestrunmode
Asthedrainpumptestrunisestablished,thedrainpumponlyoperatesandduringtheoperationprotectivefunctionsby
themicrocomputerofindoorunitbecomeineective.
(15) Heating overload protection
(a)Iftheindoorheatexchangertemperature(detectedwithThi-R)at63°Corhigherisdetectedfor2secondscontinuously,
the compressor stops.When thecompressor is restarted after a 3-minute delay,if a temperature at 63°Cor higher is
detectedfor2secondscontinuouslywithin60minutesafterinitialdetectionandifthisisdetected5timesconsecutively,
thecompressor stopswiththe anomalousstop(E8).Anomalousstopoccursalsowhentheindoor heatexchanger
temperatureat63°Corhigherisdetectedfor6minutescontinuously.
56
63
Indoor heat exchanger temperature (°C)
Compressor ON
Compressor OFF
(b) Indoor fan speed selection
If,afterseconddetection ofheatingoverload protectionupto fourth,theindoor fanissetatbelowHiwhenthe
compressor is turned ON, the indoor fan speed is increased by 1.
(16) Anomalous fan motor
(a)Afterstartingthefanmotor,ifthefanmotorspeedis200min
-1
orlessisdetectedfor30secondscontinuouslyand4
timeswithin60minutes,thenfanmotorstopswiththeanomalousstop(E16).
(b)Ifthe fan motor failstoreachat-50 min
-1
(FDU,FDUA:-500min
-1
)lessthan the required speed, itstopswiththe
anomalousstop(E20).
•Compressorforcedotemperature(FDTonly)
Hs
>
50%Hs
≦
50%
Item
Symbol
Low High
Item
Symbol
Low High
A 1.0 2.5 A -0.5
1
.0
(b) Selection of indoor fan speed
If it enters thefrost prevention controlduring cooling operation(including dehumidifying), the indoorfan speed is
switched.
(i)Whentheindoorreturnairtemperature(Thi-A)is18°Corhigherandtheindoorheatexchangertemperature(detected
withThi-R) detects thecompressorfrequencydrop start temperatureA°C+1°C,indoor fan speed isincreased by
20min
-
1
.
(ii) If the phenomenon of (i)aboveisdetectedagainaftertheaccelerationofindoorfan,indoorfanspeedisincreased
furtherby20min
-
1
.
Note (1) Indoor fan speed can be increased by up to P-Hi.
(14) Cooling, dehumidifying frost protection
(a) To prevent frosting duringcooling mode ordehumidifying mode operation, the compressor-OFF if theindoor heat
exchanger temperature (detectedwithThi-R) drops to 1.0 °C or lowerat 4 minutes after the compressor-ON. If the
indoorunitheatexchangertemperatureis1.0°Corlowerafter5minutes,theindoorunitiscontrolledcompressor-OFF.
Ifitbecomes10°Corhigher,thecontrolterminates.
•Frostpreventiontemperaturesettingcanbeselectedwiththe
indoorunitfunctionsettingofthewiredremotecontrol.
Symbol
Item
A
Temperature-Low(Factorydefault) 1.0
Temperature-High 2.5
10A
Indoor heat exchanger temperature (°C)
Compressor-OFF
Compressor-ON capable
5 minutes
timer
SRC40~60
FDC100~140
Model
Symbol
A
4
4
1
1
1.0
1.0
2.5
2.5
BC D