33
Parameter
Indica-
tion
Name Outline
Factory
Setting
80
Multi-speed setting
(speed 8)
- - -
81
Multi-speed setting
(speed 9)
- - -
82
Multi-speed setting
(speed 10)
- - -
83
Multi-speed setting
(speed 11)
- - -
84
Multi-speed setting
(speed 12)
- - -
85
Multi-speed setting
(speed 13)
- - -
86
Multi-speed setting
(speed 14)
- - -
87
Multi-speed setting
(speed 15)
Setting other than "- - -" specifies speeds 8 to 15.
By combining ON and OFF of the contact
si
g
nals
(
RH, RM, RL, REX si
g
nals
)
, the runnin
g
speed can be changed step-by-step.
Use Pr. 63 to assign the REX signal.
RH RM RL
ON
ONON
ON
REX
ON
ONONON
ON ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Speed 8
Speed 9
Speed 10
Speed 11
Speed 12
Speed 13
Speed 14
Speed 15
OFF
OFF
OFF
OFF OFF OFF
OFF
OFF
OFF
OFF
OFF
OFF
0 to 120Hz, - - -
- - -
88
PID action selection
Used to choose the operation of PID control.
20: PID reverse action,
21: PID forward action
20
89
PID proportional
band
Used to set the proportional band for PID control.
0.1 to 999%, - - -
100%
90 PID integral time
Used to set the integral time for PID control.
0.1 to 999s, - - -
1s
91 PID upper limit
Used to set the upper limit value for PID control.
0 to 100%, - - -
- - -
92 PID lower limit
Used to set the lower limit value for PID control.
0 to 100%, - - -
- - -
93
PID action set point
for PU operation
Used to set the PID action set point for PU operation.
0 to 100%
0%
94 PID differential time
Used to set the differential time for PID control.
0.01 to 10s, - - -
- - -
95 Rated motor slip
Used to set the rated motor slip to make slip
compensation.
0 to 50%, - - -
- - -
96
Slip compensation
time constant
Used to set the response time of slip compensation.
0.01 to 10s
0.5s
97
Constant-output region
slip compensation
selection
Used to choose whether slip compensation is
made or not in the constant-output region.
0, - - -
- - -
98
Automatic torque
boost selection
(Motor capacity)
You can set the motor capacity and exercise
automatic torque boost control.
"- - -" specifies V/F control.
Set the motor capacity used.
The motor capacity should be equal to or
one rank lower than the inverter capacity.
The number of motor poles should be 2, 4 or
6. (Only 4 poles for constant-torque motor)
Single-motor operation (one motor run by
one inverter) should be performed.
Wiring length from inverter to motor should
be within 30m (98.43feet).
When using a constant-torque motor, set "1" in
Pr. 71.
<Example> For 1.5kW, set "1.5".
0.1 to 3.7kW, - - -
- - -
99
Motor primary
resistance
You can set the motor's primary resistance value.
(Normally, this parameter need not be set.)
0 to 50
, - - -
- - -