_Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours.
This dries the inside of the unit.
Moisture in the air conditioner contributes to favorable conditions for
growth of fungi, such as mold.
ON/OFF
_ Press @ to stop the operation.
_Turn off the breaker and/or disconnect the power sup-
ply plug.
_ Remove all batteries from the remote controller.
When using the air conditioner again:
Clean the air filters.
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
Check that the ground wire is connected correctly.
Refer to the "PREPARATION BEFORE OPERATION",
and follow the instructions. _
Installation place
Avoid installing the air conditioner in the following places.
Where there is much machine oil.
Salty places such as the seaside.
Where sulfide gas is generated such as a hot spring.
Where oil is splashed or where the area is filled with oily smoke.
Where there is high4requency or wireless equipment.
Where the air from the outdoor unit air outlet is blocked.
Where the operation sound or air from the outdoor unit does not bother the
house next door.
sets, radios, etc }n areas where the reception is weak,
provide greater space between the outdoor unit and
tile antenna of the affected device if operation o!the air
/' '1 "%._ , ventilated dry _//'._/
IKeep asp ..... I pJace "_"/_
l i \\ \_--_lthe no_se 4,n<t00m,'n_//
II 3_ \\ \\ / ........ _" 20_,, .C/..-5
¢p........ \\3 ft<t,'n%__ TV \/ _ Irrm !...... _//;
ormo_e :///':
_'_Z pt,o,.... @/ IL_J_ -_ _ II_l'_-v _
_r' x _'or_le -L---, _ -'v_/q 5"f-K
L_4| _phone _ I_ll0ft _ / f//
Electrical work
Provide an exclusive circuit for the power supply of the air conditioner.
Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
II
Guaranteed operating range
Cooling
Upper limit
Lower limit
Upper limit
Lower limit
Heating
90°F (32.2°C) DB
73°F (22.8°C) WB
67°F (19.4°C) DB
57°F (t 3.9°C) WB
80°F (26.7°C) DB
70°F (21 .t°C) DB
tt5°F (46.t°C) DB
0°F (-17.8°C) DB
75°F (23.9°C) DB
65°F (18.3°C) WB
*4°F (_20°C) DB _t3°F (_25°C) DB
-5°F (_20.6°C) WB q4°F (_25.6°C) WB
DB : Dry Bulb
WB: Wet Bulb
Note=
If the outdoor temperature is below the lower limit of guaranteed operating
range, the outdoor unit may stop operation until the outdoor temperature
exceeds the lower limit.