®OPERATINGINSTRUCTIONS®
II
ON/OFF
Press @ to start the operation.
MODE
Press (_ to select operation mode. Each press
changes mode in the following order:
F _ -=+ © --_ 6 q
(AUTO) (COOL) (DRY) (HEAT)
TOO
........._ Press @ or @ to set the temperature_........
Each press raises or bowers the temperature by I°F
(1°C).
ON/OFF
Press @ to stop the operation.
or_,o
• The same setting is selected the next time by simply pressing @.
Operation indicator lamp
The operation indicator lamp shows the operation state of the unit.
Indication Operation state Room temperature
_'_f The unit is operating to reach the set About 4°F (2°C) or
" more away from set
"_._ temperature temperature
About 2 to 4°F (t to
"_ The room temperature is approach- 2oc) from set tem-
o ing the set temperature perature
_-_ Standby mode (only during multi
-fi._ system operation)
=in? Lighted _o'S Blinking o Not lighted
Two or more indoor units can be operated by one outdoor unit. When several
indoor units are operated simultaneously, cooling and heating operations cannot
be done at the same time. When COOL is selected with one unit and HEAT with
another or vice versa, the unit selected last goes into standby mode. The power
lamp blinks (display section).
AUTO mode (Auto change over)
The unit selects the operation mode according to the difference between the
room temperature and the set temperature. During AUTO mode, the unit
changes mode (COOL*_HEAT) when the room temperature is 4°F (2°C)
away from the set temperature for more than 15 minutes.
Note:
Auto Mode is not recommended if this indoor unit is connected to a
MXZ type outdoor unit.
Two or more indoor units can be operated by one outdoor unit. When
several indoor units are operated simultaneously, the unit may not be
able to switch operation mode between COOL and HEAT. In this case,
the indoor unit becomes standby mode.
©
6
COOL mode
Enjoy cool air at your desired temperature.
Note:
Do not operate COOL mode at very low outside temperatures (less than
14°F [-t0°C]). Water condensed in the unit may drip and wet or damage
furniture, etc.
DRY mode
Dehumidify your room. The room may be cooled slightly.
Temperature cannot be set during DRY mode.
@ HEAT mode
Enjoy warm air at your desired temperature.
When the remote controller cannot be used...
Emergency operation can be activated by pressing the emergency operation
switch (E.O.SW) on the indoor unit.
Each time the E.O.SW is pressed, the operation changes in
the following order:
Operation indicator lamp
o Emergency COOL
o
,_ Emergency HEAT
J.
o Stop
o
..,J
Note:
Set temperature : 75°F (24°C)
Fan speed : Medium
Hor zonta vane : Auto
The first 30 minutes of operation is test run. Temperature
control does not work, and fan speed is set to High.
If a power failure occurs or the main power is turned off during operation, "Auto
restart function" automatically starts operation in the same mode as the one set
with the remote controller just before the shutoff of the main power. When
timer is set, timer setting is cancelled and the unit starts operation when power
is resumed.
If you do not want to use this function, please consult the service repre-
sentative because the setting of the unit needs to be changed.
En-5