AREA SETTING
When AREA have been setted, horizontal air ow (Horizontal Vane) can adjust automatically according to the temperature measure
from the wall and oor.
Press AREA button.
Each time the button is pressed, the area is changed in sequence:
(AUTO) → (LEFT)→ (RIGHT)→Cancel
MOVE EYE Sensor moves intermittenly, measuring the oor and wall temperature.
NOTE 1: AREA setting is only available during MOVE EYE control operation. (Refer to page 34)
NOTE 2: If AREA setting is canceled, the vertical vane returns to the previously set position before AREA setting.
NOTE 3: The horizontal air ow direction (WIDE VANE button), including horizontal SWING, can not be set during AREA setting.
·
·
Moving of horizontal air ow direction
Indoor unit
display
NOTE
Day Night
Warm area
Cold area
If AREA setting is set to AUTO in heating operation, the indoor unit automatically delivers warm air to the area where the
oor/wall temperature is the lowest in the room.
If AREA setting is set to AUTO in cooling operation, the indoor unit automatically delivers cool air to the area where the
oor/wall temperature is the highest in the room.
Ex.) In heating operation
·
·
The indoor unit delivers warm air detecting the cold area in the room.
Indication of AREA setting
The horizontal air ow direction changes if MOVE EYE Sensor detects approx.3 temperature difference.
In AUTO of AREA setting, both right and left lamps are lighted when the room is evenly air-conditioned.
·
·
Not lighted
Lighted
Cancelling AREA setting
AREA setting is cancelled when the “cancel” is sellected by pressing AREA button, or when WIDE VANE button is pressed.
Indoor unit installation location and air-conditioning area.
Installation at left
Installation at center
Installation at right
LEFT RIGHT LEFT RIGHT LEFT RIGHT
Be sure to set the side switch inside the remote controler to an appropriate position in accordance with the installed position of the
indoor unit. If the switch is not set correctly, the air conditioner may not function properly. (Refer to Page 30)
·
AREA setting