24
Type
Frame (A)
250
Low-inst
Standard
Mag-Only
Generator
690V
500V
440V
400V
230V
AC Breaking
capacity (kA rms)
IEC60947-2
Icu/Ics
Number of poles
Automatic tripping
device
Rating (A) and
Inst. (A)
Automatic tripping
device
Rating (A) and
Inst. (A)
Number of poles
Number of poles
Automatic tripping
device
Rating (A) and
Inst. (A)
Number of poles
Automatic tripping
device
Rating (A) and
Inst. (A)
Rated insulation voltage Ui (V) AC
Rated current In (A)
100 ~ 125, 125 ~ 160
150 ~ 200, 200 ~ 250
690
5/3
30/8
50/13
50/13
100/25
234
Thermal, magnetic
Adjustable ampere rating and
fixed instantaneous
100 ~125 1400 ± 280
125 ~160 1400 ± 280
150 ~200 2100 ± 420
200 ~250 2500 ± 500
NF225-RPNF250-HP T/A
125, 150, 175, 200, 225
690
42/42
125/125
125/125
125/125
23
Thermal, magnetic
Fixed ampere rating and
instantaneous
Thermal, magnetic
Fixed ampere rating and
instantaneous
125 1750 ± 350
150 2100 ± 420
175 2450 ± 490
200 2800 ± 560
225 3150 ± 630
125 1750 ± 350
150 2100 ± 420
175 2450 ± 490
200 2800 ± 560
225 3150 ± 630
690
10/5
200/200
200/200
200/200
200/200
234
125, 150, 175, 200, 225
NF225-UP
225