42
How to discharge measures by water injection
CAUTION:
・The negative terminal disconnect for the 12V starter battery should be 1 minutes later the power supply
mode of the electric motor switch is turned off.
・Do not remove the service plug for 5 minutes later disconnecting the 12V starter battery negative terminal.
1) Move the vehicle to an outside well-ventilated area.
2) Turn off the Electric motor switch by pressing it. Remove the 12V starter battery negative terminal.
3) Remove the service lid cover in the footwall under the middle of the second seat.(Four clips)
4) Use an open end wrench (10mm) to remove the service lid. (four nuts)
WARNING:
Always wear Personal Protective Equipment (PPE) when pulling out the service plug.
5) Wear Personal Protective Equipment (PPE) and remove the service plug.
1. Release the lock lever on the service plug.
2. Raise the service plug lever.
3. Remove the service plug by pulling it upward.
6) Place a recovery tray of the injected water under the vehicle.
7) Fill with water that does not contain salt, such as tap water, well water or pond water through the opening on
the service lid until it is fully.