130 (244)130 (244)
PBV20N2 PBV20N2 Service Service ManualManual
9.2.3.1 9.2.3.1 Insulation Insulation resistance resistance of of the the trucktruck
Figure 77. Measuring the insulation resistance of the truckFigure 77. Measuring the insulation resistance of the truck
The insulation resistance between the live parts of all the The insulation resistance between the live parts of all the electric components and theelectric components and the
frame of the industrial truck with the exception of the battery is at least 1000frame of the industrial truck with the exception of the battery is at least 1000
ΩΩ
multiplied by the nominal voltage of the truck system.multiplied by the nominal voltage of the truck system.
NOMINAL
NOMINAL VOLTAGE VOLTAGE MINIMUM MINIMUM INSULATION INSULATION RESISTANCERESISTANCE
24 V24 V
24,000 Ω24,000 Ω
36 V36 V
36,000 Ω36,000 Ω
48 V48 V
48,000 Ω48,000 Ω
80 V80 V
80,000 Ω80,000 Ω