PBV20N2 PBV20N2 Service Service ManualManual
Figure 56. Zapi COMBIACX Power connectorsFigure 56. Zapi COMBIACX Power connectors
1.1. CND external connectorCND external connector
2.2. CNC external connectorCNC external connector
3.3. CNB external connectorCNB external connector
4.4. CNA external connectorCNA external connector
The Zapi COMBIACX Power inverter uses four connectors:The Zapi COMBIACX Power inverter uses four connectors:
CNA 14 poles CNA 14 poles connector, spare part: RL450937connector, spare part: RL450937
CNB 8 poles connector, spare part: RL450935CNB 8 poles connector, spare part: RL450935
CNC 10 poles CNC 10 poles connector, spare part: RL450936connector, spare part: RL450936
CND 6 poles connector, spare part: RL450661CND 6 poles connector, spare part: RL450661
Contact 0.2 – 0.8 mm2 for CNA, CNB, CNC and CND connectors, Spare part:Contact 0.2 – 0.8 mm2 for CNA, CNB, CNC and CND connectors, Spare part:
RL450666RL450666
8.2.3.1 8.2.3.1 CNA CNA external external connectorconnector
CONNECTION DESCRIPTION
CONNECTION DESCRIPTION
A1 EV1 (XA1 A/1)A1 EV1 (XA1 A/1)
(fan control)(fan control)
Output of the Output of the protected ON/OFF electrovalve driver;protected ON/OFF electrovalve driver;
1.5 A maximum continuous current (driving to 1.5 A maximum continuous current (driving to
Batt). Built-in freewheeling diode to B2. This outputBatt). Built-in freewheeling diode to B2. This output
is activated when the 1ST function (input is activated when the 1ST function (input A12) isA12) is
requested.requested.
A4 DI5 (XA1 A/4)A4 DI5 (XA1 A/4)
(platform up S10)(platform up S10)
Input of the switch DI5. The Input of the switch DI5. The input is activated wheninput is activated when
it is connected to +Batt. The default function is theit is connected to +Batt. The default function is the
controller HORN input. When the switch is closed,controller HORN input. When the switch is closed,
the horn output is activated.the horn output is activated.