CONNECTION DESCRIPTION
CONNECTION DESCRIPTION
A5 DI7 (XA1 A/5)A5 DI7 (XA1 A/5)
(lift cutoff option S7)(lift cutoff option S7)
Input of the switch DI7. The Input of the switch DI7. The input is activated wheninput is activated when
it is connected to +Batt. The default function is theit is connected to +Batt. The default function is the
controller LIFT enable input.controller LIFT enable input.
A6 DI9 (XA1 A/6)A6 DI9 (XA1 A/6)
(side guard out S13 & S17)(side guard out S13 & S17)
Input of the switch DI9. The Input of the switch DI9. The input is activated wheninput is activated when
the external switch is opened. The the external switch is opened. The default function isdefault function is
the controller PUMP CUTBACK input. When thethe controller PUMP CUTBACK input. When the
switch is opened, the pump speed is reduced.switch is opened, the pump speed is reduced.
A7 DI11 (XA1 A/7)A7 DI11 (XA1 A/7)
(brake release S3)(brake release S3)
Input of the switch DI11. The Input of the switch DI11. The input is activated wheninput is activated when
the external switch is opened to ground. The defaultthe external switch is opened to ground. The default
function is the controller CUTBACK1 input. Whenfunction is the controller CUTBACK1 input. When
the switch is opened, the truck speed is the switch is opened, the truck speed is reduced. Inreduced. In
the sense coil version, this input is the sense coil version, this input is connected to theconnected to the
AC motor sense AC motor sense coil.coil.
A10 GND (XA1 A/10)A10 GND (XA1 A/10)
(brake release/lift cutoff option)(brake release/lift cutoff option)
This is the ground of the logic board.This is the ground of the logic board.
A11 DI6 (XA1 A/11)A11 DI6 (XA1 A/11)
(lower switch S5)(lower switch S5)
Input of the switch DI6. The Input of the switch DI6. The input is activated wheninput is activated when
it is connected to +Batt. The default function is theit is connected to +Batt. The default function is the
controller LOWER enable input.controller LOWER enable input.
A12 DI8 (XA1 A/12)A12 DI8 (XA1 A/12)
(economy mode S1)(economy mode S1)
Input of the switch DI8. The Input of the switch DI8. The input is activated wheninput is activated when
it is connected to +Batt. The default function is theit is connected to +Batt. The default function is the
controller 1ST input: the pump motor turns controller 1ST input: the pump motor turns at theat the
defined speed.defined speed.
A13 DI10 (XA1 A/13)A13 DI10 (XA1 A/13)
(driver present / platform down S11)(driver present / platform down S11)
Input of the switch DI10. The Input of the switch DI10. The input is activated wheninput is activated when
it is connected to +Batt. The default function is theit is connected to +Batt. The default function is the
controller 2ND input: the pump motor turns at controller 2ND input: the pump motor turns at thethe
defined speed.defined speed.
A14 DI12 (XA1 A/14)A14 DI12 (XA1 A/14)
(battery lock sensor option S14)(battery lock sensor option S14)
Input of the switch DI12. The Input of the switch DI12. The input is activated wheninput is activated when
the external switch is opened to ground. The defaultthe external switch is opened to ground. The default
function is the controller CUTBACK1 input. Whenfunction is the controller CUTBACK1 input. When
the switch is opened, the truck speed is the switch is opened, the truck speed is reduced. Inreduced. In
the sense coil version, this input is the sense coil version, this input is connected to theconnected to the
AC motor sense AC motor sense coil.coil.
8.2.3.2 8.2.3.2 CNB CNB external external connectorconnector
CONNECTION DESCRIPTION
CONNECTION DESCRIPTION
B1 PEB (XA1 B/1)B1 PEB (XA1 B/1)
(magnetic brake Y31)(magnetic brake Y31)
This pin outputs the positive supply (equal This pin outputs the positive supply (equal to +Batt)to +Batt)
of the electro-mechanical brake coil. Depending onof the electro-mechanical brake coil. Depending on
the hardware configuration, this pin can bethe hardware configuration, this pin can be
controlled by the microcontroller or tied to the controlled by the microcontroller or tied to the B2B2
input or to the C6 input. See the connection drawinginput or to the C6 input. See the connection drawing
for more details.for more details.