3 - 78
3.8 I/O Processing and Response Lag
3.8.2 Direct mode
3
SEQUENCE PROGRAM CONFIGURATION AND
EXECUTION CONDITIONS
(2) Response lag
An output change lags a maximum of one scan behind an input module change
depending on the ON timing of an external contact.
Ladder examples
Figure 3.64 When DY5E turns ON fastest
Figure 3.65 When DY5E turns ON slowest
55
DX5
DY5E
Ladder that turns the DY5E output
ON when an DX5 input turns ON.
Delay time
OFF
ON
05556
External contact
OFF
ON
OFF
ON
DX5
(External contact)
DY5E
(External load)
CPU
module
devices
OFF
ON
055 56
External contact
OFF
ON
OFF
ON
DX5
(External contact)
DY5E
(External load)
CPU
module
devices
Delay time
(Maximum 1 scan)
END 0
55 56