22
-
'18 • SRK-T-250
DescriptionItem
ConnectorCNE
CNF
CNG
CNM
CNS
CNU
CNX
CNY
Power source
1 Phase
220-240V 50Hz
220V 60Hz
[ ]
F 3.15A L 250V
PRINTED
CNF CNE
CNX
CNG
4
CNU
1 3 65
CNY
M M M
5 5
2 6
2
CNS
CNM
M
5
SN
J
L
G
1
CIRCUIT
BOARD
INTERFACE KIT
RED
BLACK
WHITE
YELLOW
BLUE
WIRELESS
DISPLAY
BACK-UP SW
BLACK
WHITE
RED
YELLOWGREEN
HEAT
EXCHANGER
2N
3
YELLOWGREEN
ONLY
2 2
HEAT
EXCHANGER
5
FUSE
VARISTOR
R-AMP
TERMINAL
BLOCK
MOTOR
FAN
LEFT
MOTOR
LOUVER
MOTOR
FLAP
RIGHT
MOTOR
LOUVER
HEAT EXCHANGER
SENSOR 1
HEAT EXCHANGER
SENSOR 2
ROOM TEMP.
SENSOR
HUMIDITY
SENSOR
4
SRK35,50ZS-W
STACK
DIODE
t
o
t
o
t
o
U
TO OUTDOOR UNIT
POWER CABLE
SIGNAL WIRE
EARTH WIRE
1
3
2
RWA000Z416
3. ELECTRICAL WIRING
(1) Indoor units
Models SRK20ZS-W, 25ZS-W, 35ZS-W, 50ZS-W
SRK20ZS-WB, 25ZS-WB, 35ZS-WB, 50ZS-WB
SRK20ZS-WT, 25ZS-WT, 35ZS-WT, 50ZS-WT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SRK Series and is the answer not in the manual?

Mitsubishi SRK Series Specifications

General IconGeneral
TypeSplit System
Cooling TechnologyInverter
Power Supply220-240V, 50Hz
RefrigerantR32
Cooling CapacityVaries by model
Heating CapacityVaries by model
Energy Efficiency Ratio (EER)Varies by model
Coefficient of Performance (COP)Varies by model
Noise Level (Indoor Unit)Varies by model
Noise Level (Outdoor Unit)Varies by model
Indoor Unit Dimensions (W x H x D)Varies by model
Outdoor Unit Dimensions (W x H x D)Varies by model
Indoor Unit WeightVaries by model
Outdoor Unit WeightVaries by model

Related product manuals