 188 
-
(01)
02
03
04
05
06
07
08
(09)
10
(11)
12
13
14
15
16
17
(18)
Default
setting
GRILLE     SET
AUTO RUN SET
            TEMP S/W
            MODE S/W
                     ON/OFF S/W
        FANSPEED S/W
            LOUVER S/W
            TIMER S/W
   
SENSOR S/W
VENTI SET
TEMP RANGE SET
I/U FAN SPEED
MODEL TYPE
EXTERNAL CONTROL SET
ERROR DISP SET
 
POSITION
°C/°F SET
     INVALID
50Hz AREA ONLY
60Hz AREA ONLY
AUTO RUN ON
AUTO RUN OFF
             VALID
             INVALID
            VALID
            INVALID
        VALID
        INVALID
             VALID
             INVALID
             VALID
             INVALID
             VALID
             INVALID
    SENSOR OFF (Invalid)
    SENSOR ON (Valid)
INVALID
VALID
NO VENTI
VENTI LINK SET
NO VENTI LINK
DISP CHANGE
NO DISP CHANGE
3 FAN SPEED
2 FAN SPEED
1 FAN SPEED
HEAT PUMP
COOLING ONLY
INDIVIDUAL OPERATION
SAME OPERATION FOR ALL UNITS
ERROR DISP
NO ERROR DISP
FIX (1 OF 4) (4 position stop)
IN MOTION (Free stop)
°C
°F
Grille lift 
panel setting
Remote control
sensor setting
Indoor unit
fan speed setting
ON/OFF
Louver
control setting
(01)
(03)
04
05
06
(07)
(08)
(09)
(10)
Function
number  A
Default
setting
Hi CEILING SET
FILTER SIGN SET
 
POSITION
EXTERNAL INPUT SET
 
ROOM TEMP OFFSET
       FAN CONTROL
FREEZE PREVENT TEMP
FREEZE PREVENT CONTROL
(Heating room temperature offset)
Heating
fan control
Louver control
setting
STANDARD (Mild mode)
Hi CEILING 1
 (Powerful mode)
NO DISPLAY
AFTER 180H
AFTER 600H
AFTER 1000H
1000H→STOP
FIX (1 OF 4) (4 positiion stop)
IN MOTION (Free stop)
LEVEL INPUT
PULSE INPUT
NORMAL OPERATION
VALID
NORMAL OPERATION
TEMP SHIFT +3˚C
LOW FAN
STOP→LOW FAN (Intermittent operation)
TEMP Hi
TEMP Lo
FAN CONTROL ON
FAN CONTROL OFF
Function description  
B
Setting  
C
Function
number  A
Function description  
B
Setting  
C
()
()
()
()
POWER FAILURE 
COMPENSATION SET
()
()
OPERATION PERMISSION 
PROHIBITED
Notes(1)
(2)
(3)
Setting marked with [嘷] are the default setting.
Setting marked with [
*
] are those that are set automatically 
according to an indoor unit or an outdoor unit connected.
Please check default settings with the indoor unit's installation 
manual.
The SRK model cannot set the items described in (  ) in the 
function number A.
Notes(1)
(2)
(3)
(4)
Setting marked with [嘷] are the default setting.
Setting marked with [
*
] are those that are set automatically 
according to an indoor unit or an outdoor unit connected.
Please check default settings with the indoor unit's installation 
manual.
When Item 17 : “          POSITION” is changed, please also 
change Item 04  “         POSITION” setting found in  
“Indoor unit functions”.
The SRK model cannot set the items described in (  ) in the 
function number A. 
*
*
*
*
(c) Setting functions using the wired remote control
(i) The default settings of this unit's functions are as follows: If you want to charge a setting, follow the procedure found in the
installation manual and set to your desired setting.
   For the method of setting, please refer to the installation manual of a remote control unit.
1 Remote control unit functions (
 
 FUNCTION  )
2 Indoor unit functions (I/U FUNCTION 
 )