52
-
'13 • SRK-T-140
'09•SRK-DB-087D
Over heat of compressor
Gas shortage, defective discharge
pipe sensor
Error of signal transmission
Wiring error including power cable, defective indoor/
outdoor PCB
51)
'09•SRK-DB-087D
Current cut
Compressor lock, Compressor wiring short circuit, Compressor output is open phase,
Outdoor PCB is faulty, Service valve is closed, EEV is faulty, Compressor faulty.
Current safe stop
Overload operation, compressor
lock, overcharge
59
57
SRK25, 35 : 4.293Ω (U-V, V-W, U-W) or more at 20ºC
SRK45 : 1.104Ω (U-V, V-W, U-W) or more at 20ºC