heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -
heating / Colder Pdesignh - kW heating / Colder SCOP/C - -
unit
Declared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignh
heating / Average (-10℃) Pdh 2.54 kW heating / Average (-10℃) elbu 0.46 kW
heating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kW
heating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW
Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ and
outdoor temperature Tj outdoor temperature Tj
Tj=35℃ Pdc 3.2 kW Tj=35℃ EERd 3.22 -
Tj=30℃ Pdc 2.36 kW Tj=30℃ EERd 5.16 -
Tj=25℃ Pdc 1.52 kW Tj=25℃ EERd 8.97 -
Tj=20℃ Pdc 1.86 kW Tj=20℃ EERd 9.75 -
Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoor
temperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature Tj
Tj=-7℃ Pdh 2.65 kW Tj=-7℃ COPd 2.28 -
Tj=2℃ Pdh 1.62 kW Tj=2℃ COPd 4.08 -
Tj=7℃ Pdh 1.04 kW Tj=7℃ COPd 5.34 -
Tj=12℃ Pdh 1.07 kW Tj=12℃ COPd 6.54 -
Tj=bivalent temperature Pdh 2.65 kW Tj=bivalent temperature COPd 2.28 -
Tj=operating limit Pdh 2.35 kW Tj=operating limit COPd 2.13 -
Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoor
temperature 20℃ and outdoor temperature Tj
temperature 20℃ and outdoor temperature Tj
Tj=2℃ Pdh - kW Tj=2℃ COPd - -
Tj=7℃ Pdh - kW Tj=7℃ COPd - -
Tj=12℃ Pdh - kW Tj=12℃ COPd - -
Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -
Tj=operating limit Pdh - kW Tj=operating limit COPd - -
Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoor
temperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature Tj
Tj=-7℃ Pdh - kW Tj=-7℃ COPd - -
Tj=2℃ Pdh - kW Tj=2℃ COPd - -
Tj=7℃ Pdh - kW Tj=7℃ COPd - -
Tj=12℃ Pdh - kW Tj=12℃ COPd - -
Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -
Tj=operating limit Pdh - kW Tj=operating limit COPd - -
Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -
Bivalent temperature Operating limit temperature
heating / Average Tbiv -7 ℃ heating / Average Tol -15 ℃
heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃
heating / Colder Tbiv - ℃ heating / Colder Tol - ℃
Cycling interval capacit
nnual electricity consumption
off mode Poff 6 W cooling Qce 183 kWh/a
standby mode Psb 6 W heating / Average Qhe 1052 kWh/a
thermostat-off mode Pto 25 W heating / Warmer Qhe - kWh/a
crankcase heater mode Pck 0 W heating / colder Qhe - kWh/a
Capacity control(indicate one of three options) Other items
Sound power level(indoor) Lwa 60 dB(A)
Sound power level(outdoor) Lwa 60 dB(A)
fixed No Global warming potential GWP 1975 kgCO2eq.
staged No Rated air flow(indoor) - 570 m3/h
variable Yes Rated air flow(outdoor) - 1524 m3/h
Contact details for obtaining Name and address of the manufacturer or of its authorised representative.
more information
RWA000Z249-8
Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.
7 Roundwood Avenue, Stockley Park, Uxbridge, Middlesex, UB11 1AX,
United Kingdom