EasyManua.ls Logo

Mitsubishi SUZ-KA30NA - TROUBLE CRITERION OF MAIN PARTS

Mitsubishi SUZ-KA30NA
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
OCH688A
10-4. TROUBLE CRITERION OF MAIN PARTS
SUZ-KA18NA(H)2.TH SUZ-KA24NA(H)2.TH SUZ-KA30NA(H)2.TH SUZ-KA36NA(H)2.TH
Part name Check method and criterion Figure
Defrost thermistor (RT61)
Fin temperature
thermistor (RT64)
Ambient temperature
thermistor (RT65)
Outdoor heat exchanger
temperature thermistor
(RT68)
Measure the resistance with a tester.
Refer to “Inverter P.C. board” in "10-6. TEST POINT DIAGRAM AND
VOLTAGE”, for the chart of thermistor.
Discharge temperature
thermistor (RT62)
Measure the resistance with a tester. Before measurement, hold the
thermistor with your hands to warm it up.
Refer to “Inverter P.C. board” in "10-6. TEST POINT DIAGRAM AND
VOLTAGE”, for the chart of thermistor.
Compressor
Measure the resistance between terminals with a tester.
(Temperature: 14 to 104 °F (-10 to 40 °C))
1RUPDO
KA18 KA24/30/36
U-V
U-W
V-W
0.82 to 1.11 0.83 to 1.03
Outdoor fan motor
Measure the resistance between lead wires with a tester.
(Temperature: 14 ~ 104 °F (-10 ~ 40 °C))
Color of lead wire
1RUPDO
KA18 KA24/30/36
RD – BK
BK – WH
WH – RD
12 to 16 12 to 17
R. V. coil (21S4)
Measure the resistance with a tester.
(Temperature: 14 to 104 °F (-10 to 40°C))
1RUPDON
0.97 to 1.38
Expansion valve coil
(LEV)
Measure the resistance with a tester.
(Temperature: 14 ~ 104 °F (-10 ~ 40 °C))
Color of lead wire 1RUPDO
RD – OG
37 to 54
RD – WH
RD – BU
RD – YE
Defrost heater
(SUZ-KA·NAH2)
Measure the resistance using a tester.
[Temperature: 14 - 104°F (-10 - 40°C)]
1RUPDON
349 to 428
W
U
V
WH
RD BK
WH
RD BK
LEV
WH
RD
YE
OG
BU

Table of Contents