14
Unit: mm
30
35
155
90
198
40
515
299
66
34
51
330
360
850
430
500
80
121
840
Open as a rule
500mm or more if
the front and both
sides are open
100mm or more
200mm or more if
there are obstacles
to both sides
Open as a rule
500mm or more if the back,
both sides and top are open
350mm or more
100mm or more
Service panel
Gas refrigerant
pipe joint
Refrigerant pipe(flared)
:12.7·····(SUZ-KA50VA)
:15.88···(SUZ-KA60/KA71VA)
Liquid refrigerant
pipe joint
Refrigerant pipe(flared)
:6.35·····(SUZ-KA50/KA60VA)
:9.52·····(SUZ-KA71VA)
REQUIRED SPACE
Drain holes :33
OUTDOOR UNIT
SUZ-KA50VA.TH SUZ-KA50VA1.TH SUZ-KA50VAR2.TH
SUZ-KA60VA.TH SUZ-KA60VA
1.TH SUZ-KA60VAR2.TH
SUZ-KA71VA.TH SUZ-KA71VA
1.TH
OC322G