8
SPECIFICATION
4
Function
Power supply
Outdoor Service Ref.
Starting current *1
Compressor motor current *1
Fan motor current *1
Model
Output
Winding
resistance (at 20)
Model
Winding
resistance(at 20)
Air flow(High/Low+)
Dimensions WHD
Weight
Sound level
*1
Fan speed(High
+
/Low
+
, High
+
/Med
+
/Low
+
)
Fan speed regulator
Refrigerant filling
capacity(R410A)
Refrigerating oil (Model)
A
A
A
W
*/h
mm
kg
dB
rpm
kg
cc
Single phase
230V, 50Hz
3.65
KNB073FDVH(C)
550
U-V 1.53 U-W 1.53
V-W 1.53
RC0J50-AL
WHT-BLK 37.5
BLK-RED 37.5
RED-WHT 37.5
800%550%285
33
46
0.90
320 (NEO22)
Cooling
2.74
0.31
2,058
810
+
/650
+
2
880
+
/810
+
/650
+
3
810
+
/650
+
2
880
+
/810
+
/650
+
3
Heating
3.37
0.28
1,938
SUZ-KA25VA(H).TH
Compressor
Fan
motor
Special
remarks
Electrical
data
SUZ-KA25VA(H)R1.TH
Single phase
230V, 50Hz
3.65
KNB073FFDH(C)
550
U-V 1.70 U-W 1.70
V-W 1.70
RC0J50-DB
WHT-BLK 37.0
BLK-RED 37.0
RED-WHT 37.0
800%550%285
30
46
0.80
320 (NEO22)
Cooling
2.74
0.31
2,058
Heating
3.37
0.28
1,938
SUZ-KA50VA.TH
SUZ-KA50VA
1.TH
Single phase
230V, 50Hz
6.75
0.30
SNB130FLDH or SNB130FLDH1
850
U-V 0.45 U-W 0.45
V-W 0.45
RC0J60-AA
WHT-BLK 15.2
BLK-RED 15.2
RED-WHT 15.2
840%850%330
53
2
1.60
FLDH: 450/FLDH1: 600(NEO22)
Cooling
6.45
2,940/1,650
+
53/51
+
800/480
+
Heating
6.05
2,940/2,210
+
55/53
+
800/620
+
Capa-
city
SUZ-KA35VA(H)R1.TH
840
+
/760
+
2
880
+
/800
+
/630
+
3
SUZ-KA35VA(H).TH
Single phase
230V, 50Hz
4.75
KNB092FCAH
650
U-V 0.49 U-W 0.49
V-W 0.49
RC0J50-AL
WHT-BLK 37.5
BLK-RED 37.5
RED-WHT 37.5
2,004
800%550%285
37
1.05
320 (NEO22)
Cooling
4.22
0.33
47
Heating
4.42
0.33
48
840
+
/760
+
2
880
+
/800
+
/630
+
3
Single phase
230V, 50Hz
4.75
KNB092FFAH(C)
650
U-V 1.91 U-W 1.91
V-W 1.91
RC0J50-DB
WHT-BLK 37.0
BLK-RED 37.0
RED-WHT 37.0
2,004
800%550%285
33
1.05
320 (NEO22)
Cooling
4.22
0.33
47
Heating
4.42
0.33
48
NOTE : Test conditions are based on ISO 5151
Cooling : Indoor D.B. 27: W.B. 19:
Outdoor D.B. 35: W.B. 24:
Heating : Indoor D.B. 20: W.B. 15:
Outdoor D.B. 7: W.B. 6:
Refrigerant piping length (one way): 5m
*1 Measured under rated operating frequency.
w Reference value
OC322G