EasyManua.ls Logo

Mitsubishi SUZ-KA35VA - Test Point Diagrams

Mitsubishi SUZ-KA35VA
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
96
Back side of unit
-20 -10 0 10 20 30 40
0
10
20
30
40
50
60
70
80
90
100
Temperature()
Ambient temperature thermistor(RT65)
Defrost thermistor(RT61)
Temperature()
Discharge temperature thermistor(RT62)
0 10 20 30 40 50 60 70 80 90 100 110 120
0
100
200
300
400
500
600
700
0 1020304050607080
0
20
40
60
80
100
120
140
160
180
200
Tem
p
erature
(
)
Fin temperature thermistor(RT64)
Resistance(k)
Resistance(k)
Resistance(k)
Output to drive
outdoor fan motor
(CN932)
Fin temperature
thermistor/RT64
(CN642)
Ambient temperature
thermistor /RT65
(CN643)
Discharge temperature
thermistor/RT62
(CN641)
Defrost thermistor/RT61
(CN641)
LEV
connector
(CN724)
230V AC
DB61
Connecting wire with
power P.C. board
(CN725)
Jumper wire for change
in defrost setting (JS)
Front side of unit
DB61
280V ~ 370V
DC
Smoothing capacitor
(C63C)
Smoothing capacitor
(C63A)
Smoothing capacitor
(C63B)
Rotational frequency
feedback signal of outdoor fan motor
(CN931)
1(+)
2(+)
3(+)
4
5V
5
GND
Output to
drive
compressor
(LDW,
LDV,
LDU)
LED monitor
lamp
Connector for indoor/
outdoor communication
(CN601)
(+)
(-)
12-6. Test point diagram and voltage
12-6-1. Inverter P.C. board
SUZ-KA25VA.TH SUZ-KA35VA.TH
SUZ-KA25VAH.TH SUZ-KA35VAH.TH
Fuse
(F801)
Fuse
(F901)
OC322G