3 Caution on welding works
Battery terminals must be detached before welding. Do not position the ground terminal near the electronic parts or
the electronic parts lie between it and the area to be weld to prevent damage.
Even the parts have switches. But still must follow the guidelines below.
1) Detached the battery terminal
2) Position the ground terminal near the object to be weld.
(b) Wire selection
For heat resistance wire, refer to the table below.
(JASO D 609: Applicable current for low voltage wire for automobile).
A void installing the wire at temperature above 70°C. If necessary use AEX type of wire.
(10) Installation of marker lamp (user’s option)
Notes:
1. When installing marker lamp (users option) at the side of refrigeration unit. It must be installed according to the
dimension shown in this drawing. (Both sides of cover)
2. Marker lamp is not included in the refrigeration unit, it must be prepared separately.
3. Unit: mm
86
Type of wire Ambient temp. Remarks
AV wire
60°C of below Applicable at ordinary condition
(Low voltage wire for automobile)
AXV wire
70°C of below
AEX wire
90°C of below
Applicable near the engine or at
any heat source
Applicable near the engine or at
any heat source
(Heat resistance low voltage
wire for automobile)
(High temp. heat resistance low
voltage wire for automobile)