EasyManua.ls Logo

Mitsubishi TRUYA0361KA80NA - Page 44

Mitsubishi TRUYA0361KA80NA
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
45
44
TCHT011
1
A
B
2
3
13-4-2. PAR-SL101A-E
1. Press the button to stop the air conditioner.
• If the weekly timer is enabled (
is on), press the
button to disable it ( is off).
2. Press the
button for 5 seconds.
comes on and the unit enters the service mode.
3. Press the
button .
comes on and the unit enters the test run mode.
4. Press the following buttons to start the test run.
: Switch the operation mode between cooling and heating
and start the test run.
: Switch the fan speed and start the test run.
: Switch the airflow direction and start the test run.
: Switch the louver and start the test run.
: Start the test run.
5. Stop the test run.
• Press the
button to stop the test run.
After 2 hours, the stop signal is transmitted.