LOCK PROGRAMMING
1. Programming a new guest door lock.
1. Turn on the DTU
2. Sign in with your staff code and password, then press Enter
3. Press the #1 button for R/C
4. Select F1 for Normal Mode
5. Select F4 for Data Mode
6. Room Type is 02 for guest doors, press Enter
7. Input the room number and press enter three times
8. Input the floor number and press enter three times.
9. Hold the DTU card to the lock, when you have orange LED, Aim unit at lock and press SEND/RCV
10. DTU will say “Try Connect” and “Loading Success” when finished
2. Programming a new lock as a common door.
1. Turn on the DTU
2. Sign in with your staff code and password, then press Enter
3. Press the #1 button for R/C
4. Select F1 for Normal Mode
5. Select F4 for Data Mode
6. Room type is 01 common doors, press the up arrow one time to select, press Enter three times
7. Input a Room Number to identify this door, press Enter three times
8. Input a Floor Number and press Enter three times
9. Input Room Range, type lowest room number and press Enter, then type highest room number and press Enter three
times
10. Press Enter to bypass Special Number
11. Press Enter to bypass Non-Guest Number
12. Press Enter two times then input Guest Valid Time. Using military time type the time a card will start working in lock (i.e.
0600) the time card stops working in lock (i.e. 2100), type all eight numbers before pressing Enter three times
13. Input days of the week, (by default 1234567 should be on screen). Press Enter
14. If you want the door to stay open automatically, you will need to set a Time Zone, Option 01 should be Unset. If it is not,
use the down arrow button to select Unset option.
15. Time Zone. Input the time you want the door to unlock and then the time you want door to lock. Example – 06002200
and press Enter three times. All zeros by default and the door is locked all the time
16. Hold the DTU card to the lock, when you have orange LED, Aim unit at lock and press SEND/RCV
17. DTU will say “Try Connect” and “Loading Success” when finished