71
Electromagnetic Flow Meter
FW: 841012/842009
Resettable Forward Totalizer
RFTot
The Totalizer counts the forward flow volume according to the primary
flow direction selected at startup.
The Totalizer counts in selected units and is resettable.
The counter can be connected to the relays or to the display only.
To reset the counter, the totalizer must be present in the Main display
and be selected by the up/down keys followed by a click on Reset.
Alternatively it can be reset via the digital input DI.
Resettable Reverse Totalizer
RRTot
The Totalizer counts the reverse flow volume according to the primary
flow direction selected at startup.
The Totalizer counts in selected units and is resettable.
The counter can be connected to the relays or to the display only.
To reset the counter, the totalizer must be present in the Main display
and be selected by the up/down keys followed by a click on Reset.
Alternatively it can be reset via the digital input DI.
Resettable Sum Totalizer
RSTot
The Totalizer counts the sum of forward flow volume minus the reverse
flow volume according to the primary flow direction selected at startup.
The Totalizer counts in selected units and is resettable.
The counter can be connected to the relays or to the display only.
To reset the counter, the totalizer must be present in the Main display
and be selected by the up/down keys followed by a click on Reset.
Alternatively it can be reset via the digital input DI.