MAINTENANCE AND SERVICE INSTRUCTIONS | 17
E. After start up and the V-2Esc is vibrating, check as follows:
a) Visually, from a safe distance, inspect the hydraulic lines for leaks.
b) Beforeattachingtopile,openandcloseclampjawstoverifyfastandpositiveaction.
c) Be sure that there are no kinks in the lines and that they hang uniformly.
d) Always maintain a close check on the lifting cable to assure no fraying has occurred.
e) Check for overheated bearing housings.
F. Clamp Pressure - 2,500 PSI
G. Hydraulic Oil Temperature - 115 degrees Fahrenheit to 165 degrees Fahrenheit