16 | MAINTENANCE AND SERVICE INSTRUCTIONS
VI MAINTENANCE AND SERVICE INSTRUCTIONS
A. The V-2Esc hammer should be inspected regularly to help keep it in good operating
condition.Thetimeintervalbetweennecessaryadjustmentsandrepairsdepends
primarily on how much and how hard the machine has been used. Repair or replace
broken or damaged parts as soon as they are discovered. Periodic cleaning and
repainting will help keep all parts in better working order and prolong the machine’s life.
B. Inspect the V-2Esc hammer daily for loose fasteners.
Stand a safe distance away from the pile and from below the
V-2Esc hammer during vibrating operations. Any unobserved or unconnected,
loose nut or other fastener may fall.
C. Assure that the proper lube oil level is maintained in the V-2Esc exciter case. If the level
of oil is above the sight gauge or the lube oil volume is increasing, this will indicate that
thehydraulicmotorisleakinghydraulicuidthroughthemotordriveshaftseal.Theseal
leakage must be corrected immediately.
D. Daily Maintenance Check Lists - Check the entire unit prior to and during start-up each
shift.
a) Visually check all hoses for signs of damage or cuts that might cause hose failure
during operation. Be sure all connections are tight, especially the quick disconnects.
b) Look for any damage to the unit, in general that might cause it to fail when put into
operation.
c) Check the V-2Esc exciter case lube oil level.
d) ChecktheV-2Escclampingjawsforexcessivewear,cracksorloosefasteners.If
itisnecessary,theremovalofthemovablejawisdonebypushingoutthe3/4”roll
pineitherupordown.Thesingleverticalrollpincaptivatesthemovablejaw.The
xedjawisheldtightagainstthehousingwithtwoone-inchbolts.Also,operatingthe
V-2EsconpilingwithouttheJawShieldscouldresultinjawdamageifthehammeris
dropped onto the pile.