TROUBLESHOOTING:
Possible shorted cell or discharged battery
All connections must be tight and free of corrosion
Use jumper cable to bypass solenoid. If motor runs,
solenoid is defective and needs replacing
Check other wire connections
Ammeter jumps back and forth
Circuit breaker on charger
Motor runs - will not raise or hold
position
Release valve rod in pump
Be sure rod is not binding. Remove from pump and
allow oil to drain from port to flush possible dirt from
pump.
Check oil level in reservoir
If low, fill to capacity - 1" from filler hole
Tap solenoid switch lightly on side to release contact
wire
Carriage lowers too slowly
Remove assembly and let oil drain from unit to flush the
opening. Reassemble.