在地面排污口上画十字标记
将地面清洁干净,同时将水分擦干。
Make a cross mark on the floor drain
Clean the floor and dry the water.
3
以前的供水角阀
The previous
angle valve
地面排污口
Floor drain
十字标记
Cross mark
带接地、防水、
防溅电源插座
With a grounded,
waterproof,
splash-proof
power outlet
水压的确认
最低动态工作水压为0.14MPa(流动时18L/min 以上),另外
最高静态水压为0.75MPa(静止时)。未能满足此最低水压
时,则无法达到最佳的冲水效果。
最低水压测定要领,没有水压测定器的话,可参考此方法。
打开供水角阀,测量10秒钟流出的水量只要超过3升,说明水压
符合坐便器安装指标。(使用工具:秒表、量杯。)
Confirm the water pressure
Water Pressure 0.14Mpa (dynamic) - 0.75Mpa (static).
If can't satisfy the min water pressure, the best flushing
effect cannot be achieved.
The best way to test the min water pressure, without a water
pressure tester, refer to this method.
Open the water supply angle valve, measuring the amount of
water flow rate within 10 seconds. If it exceeds 3 liters, it
indicates that the water pressure meets the installation index
of the toilet.
(Use tools: stopwatch, measuring cup.)