6 44D0060
PRODUCT FEATURES AND SPECIFICATIONS
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
DEB20NM MANUAL 28,000 18,000
DEB24NM MANUAL 38,000 20,000
DEB30NM MANUAL 38,000 20,000
DEB20NV MILLI-VOLT 28,000 18,000
DEB24NV MILLI-VOLT 38,000 25,000
DEB30NV MILLI-VOLT 38,000 25,000
DEB20NH HI/LO 28,000 18,000
DEB24NH HI/LO 38,000 20,000
DEB30NH HI/LO 38,000 20,000
DEB20NT THERMOSTAT 28,000 18,000
DEB24NT THERMOSTAT 38,000 25,000
DEB30NT THERMOSTAT 38,000 25,000
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
DEB20PM MANUAL 28,000 18,000
DEB24PM MANUAL 38,000 20,000
DEB30PM MANUAL 38,000 20,000
DEB20PV MILLI-VOLT 28,000 20,000
DEB24 PV MILLI-VOLT 38,000 30,000
DEB30PV MILLI-VOLT 38,000 30,000
DEB20PH HI/LO 28,000 21,000
DEB24PH HI/LO 38,000 22,000
DEB30PH HI/LO 38,000 22,000
DEB20PT THERMOSTAT 28,000 20,000
DEB24PT THERMOSTAT 38,000 30,000
DEB30PT THERMOSTAT 38,000 30,000
NATURAL GAS
NOTE: An external regulator is required to reduce supply pressure to a maximum of 10
1
/2" W.C. (11"
W.C. for HI/LO) on natural gas systems operating at higher pressure.
Manual Pressure Milli-Volt and T-Stat Pressure Hi/Lo Pressure
Regulator Pressure: Setting: 3.0" w.c. Regulator Pressure Setting: 3.5" w.c. Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c. Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max. 10
1
/2" w.c. Gas Inlet Pressure: 10
1
/2" w.c. Gas Inlet Pressure: Max. 11" w.c.
Min. 5" w.c. Min. 5" w.c. Min. 6" w.c.
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Manual Pressure Milli-Volt and T-Stat Pressure Hi/Lo Pressure
Regulator Pressure Setting: 10" w.c. Regulator Pressure Setting: 10" w.c. Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Max. 13" w.c. Gas Inlet Pressure: Max. 13" w.c. Gas Inlet Pressure: Max. 13: w.c.
Min. 11" w.c. Min. 11" w.c. Min. 12" w.c.