Entry/Exit Delays (cont’d)
Exit Alarms
Exit Error Conditions
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior
zone is faulted before exit delay expires and remains faulted (e.g., exit door left open),
the system sounds an alarm and starts the entry delay timer. If you disarm the
system before the entry delay ends, the alarm sound stops and the message
"CANCELED ALARM" or "CA" is displayed on the keypad, along with a zone number
indicating the faulted zone. No message is sent to the Central Monitoring Station.
To clear the exit error condition, the open zone must be made intact; to clear the
display, enter your code plus OFF.
If you do not disarm the system before the entry delay ends and the faulted zone
remains open, the alarm sound continues and an "exit alarm" message is sent to the
Central Monitoring Station (after the installer-programmed dial delay expires). The
message "EXIT ALARM" or "EA" is displayed on the keypad, along with a zone
number indicating the faulted zone. To stop the alarm, the system must be disarmed
(your code plus OFF); to clear the display, enter your code plus OFF a second time.
An “exit alarm” also results if an entry/exit door or interior zone is faulted within two
minutes after the end of the exit delay.
Your system may have been programmed for this feature to minimize false alarms sent to the Central Monitoring
Station. Ask your installer if "Exit Alarm" is active in your system. If so, check this box.