9. 7.0 IDEAL OPERATING CONDITIONS
Room should be allowed for the door to open fully to allow easy loading and unloading of
product without people coming in contact with hot surfaces.
To ensure that operators do not slip. The floor area around the oven should be kept clean
and free from spilt fat etc
Racks should be available to allow cooked products to cool safely.
Oven gloves should be available at all times.
It is the customers’ sole responsibility to arrange adequate ventilation and it should be
sufficient to ensure water does not condense on or around the oven. A 50mm gap is
required at the sides and rear of this oven and at least 150mm on top.
Chimneys and evacuation ducts, fitted above mono ovens should be insulated
AMBIENT WORKING TEMPERATURES.
Ambient working temperatures for electric/electronic components such as
solenoid switches, circuit breakers, motors etc should be no more than 40C (115 f)
Manufacturers of these and other electrical components advise that any ambient temperature
above 40
C affects the functionality of the components and any related guarantees become
void. For example, above this temperature motors are not satisfactorily cooled, contactor
efficiency is seriously impaired and electronic components shut down. It is the customers’ sole
responsibility to arrange for adequate ventilation. Any component malfunctioning during the
guarantee period that is found to have been subject to excessive humidity or ambient working
temperature above 40
C (115
F) will not be covered by the component manufacturers
guarantee or MONO’s product warranty.