EasyManua.ls Logo

Monster AVS 2000 - Troubleshooting; Power and Overload Issues

Monster AVS 2000
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
TROUBLESHOOTING
Symptom Possible Cause Remedy
The Monster
AVS 2000 is not
receiving power.
The Monster AVS 2000
is not turned On.
• Make sure the Monster AVS 2000’s AC power plug
is plugged into a properly grounded 120V
wall outlet.
• Press the ON button on the Monster AVS 2000.
• In some households, a wall switch may need
to be thrown to make the wall outlet come alive.
Try turning on the light switches located near
the wall outlet powering the Monster AVS 2000.
Too many devices are connected, causing
an overload, tripping the thermal circuit
breaker. Please note: The total power
consumption on all the components
powered by a single Monster AVS 2000
should not exceed 1800 watts.
• Disconnect any component that maybe overloading
the Monster AVS 2000.
• Press the Monster AVS 2000’s thermal circuit
breaker (labeled Breaker 15A on the back panel)
button in to reset. Please allow 10 minutes from
the time the circuit breaker is initially tripped
before attempting to reset. If you reset too soon,
the breaker will prematurely sense power overload
and not allow the unit to operate.

Related product manuals