GARMIN G1000 ANNUNCIATIONS AND WARNING LIGHTS
ANNUNCIATION
FUNCTION
ANNUNCIATION
COLOR
ANNUNCIATION
TRIGGER
ACTION
WHEN ON
ACTION
WHEN OFF
GEAR DOWN GREEN GREEN GEAR DOWN DISPLAYED ON G1000 STEADY
GREEN
“GEAR DOWN”
OFF WHEN
GEAR IS UP
GEAR UNSAFE RED RED GEAR UNSAFE DISPLAYED ON G1000.
DISPLAYS ALSO DURING GEAR TRANSITION
STEADY RED
“GEAR UN-
SAFE”
OFF WHEN
GEAR IS UP OR
DOWN
SPEEDBRAKE WHITE WHITE SPEED BRAKE DISPLAYED ON G1000. STEADY WHITE
“SPEEDBRAKE”
OFF WHEN
SPEEDBRAKES
ARE RETRAC-
TED
ALTERNATE AIR AMBER AMBER ALT AIR WHEN ALTERNATE AIR
HANDLE IS PULLED OUT.
STEADY AM-
BER
“ALT AIR”
OFF WHEN AL-
TERNATE AIR
HANDLE IS
PUSHED IN
PROP DE-ICE AMBER If system is operating properly, the GREEN PROP
DE-ICE switch lamp is illuminated, and the G1000
shows no annunciation. Amber PROP DE-ICE if
the PROP DE-ICE switch is in ON position with
Green PROP DE-ICE switch lamp illuminated, but
PROP DE-ICE system has failed. NOTE: PROP
DE-ICE is only an option for aircraft without TKS
installed.
STEADY AM-
BER
“PROP DE-ICE”
OFF WHEN
PROP DE-ICE
SWITCH IS
SELECTED OFF
PITOT HEAT AMBER If system is operating properly, the GREEN Pitot
Heat switch lamp is illuminated, and the G1000
shows no annunciation. AMBER PITOT HEAT if
the PITOT HEAT switch is in ON position with
Green PITOT HEAT switch lamp illuminated, but
Pitot Heat system has failed.
STEADY AM-
BER
“PITOT HEAT”
OFF WHEN
PITOT HEAT
SWITCH IS
SELECTED OFF
ALTERNATOR
FAIL
RED RED ALT FAIL on G1000 Display when Alternator
output goes to zero, or when Field shorts. NOTE:
Voltmeter on MFD Display flashes YELLOW when
bus voltage drops below @24.5VDC whether al-
ternator has failed or not.
STEADY RED
“ALT FAIL”
OFF WHEN
ALTERNATOR
OUTPUT IS
NORMAL
START POWER RED RED START POWER
DISPLAYED ON WHEN STARTER IS ENGAGED
STEADY RED
“START
POWER”
OFF WHEN
STARTER IS
NOT ENGAGED
EMERGENCY
BUS
AMBER AMBER EMER BUS Displayed on G1000 when
EMERGENCY BUS switch is selected ON. Green
lamp on Emergency Bus switch when switch is
selected ON
STEADY RED
“EMER BUS”
OFF WHEN
EMERGENCY
BUS NOT
ENERGIZED
DOOR OPEN RED RED DOOR OPEN Displayed on G1000 when
either cabin door(s) or baggage door is not shut.
STEADY RED
“DOOR OPEN”
OFF WHEN
ALL DOORS
ARE SHUT
LOW BOOST
PUMP
WHITE
LOW BOOST: GREEN lamp illuminated on LOW BOOST
Switch. WHITE low boost Illuminated on Annunciation.
STEADY WHITE
“LOW BOOST”
OFF WHEN
LOW BOOST
PUMP SWITCH
IS SELECTED
OFF
HIGH BOOST
PUMP
AMBER AMBER HIGH BOOST Displayed on G1000.
NOTE: The HIGH BOOST switch has a thumb
lock- out to prevent accidental operation instead of
agreenlamp.
STEADY AM-
BER
“HIGH BOOST”
OFF WHEN
HIGH BOOST
PUMP SWITCH
IS SELECTED
OFF
24-33-00