15. Clean the bottom of the tank of any debris, excess paint, and rust.
16. If your tank sits directly on the ground or other flat surface, then install the spacers to the bottom of
the foot ring of your tank. This will provide adequate space and improved wireless range for the sensor.
Steel Tanks:
17. The sensor mounts to the bottom center of the tank using magnets. The rubber pad between the
magnets must make good contact with the tank, with no contaminants in between and must be aligned to
the bottom center of the tank.
18. Apply a generous amount of the supplied sonic grease directly to the rubber pad before attaching sensor
to the tank.
19. Install sensor on tank such that rubber pad is aligned with the bottom, center of tank.