EasyManua.ls Logo

Morso 2110 - Page 14

Morso 2110
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
DK ENG
The maximum recommended weight of wood fuel per load is 2.5 kg/h/5.5Ibs (approx 3 split
logs).
Under normal ring, the average ue temperature in the stove pipe, measured 20 cm above
the stove, is approx. 300° C (550°F). The maximum ue temperature in the stove pipe must
not exceed 450° C (75F). If the ue temperature exceeds 450°C (75F), it is considered
as over ring and may cause premature wear and tear of the stove.
To help gauge the correct running temperature of your stove, we recommend you use the Mor
Flue Gas Thermometer (part #62901200). The Flue Gas Thermometer magnetically attaches onto
the stove pipe approx 20 cm (8”) above the stove’s top plate and measures the surface temperature
of the stove pipe. Please see your authorized Morsø Dealer for availability.
Draft conditions
If smoke or fumes come out of your stove when lightning up and reloading, or if the re simply
will not respond, a poor draft is almost certainly to blame. (In a very few cases, there may be
insucient fresh air getting into the room - see installation advice above). Take advice from
your stove supplier on how best to upgrade your ue system to improve draft.
Rules of woodburning
If you want less heat, put fewer logs on the stove and reduce the amount of air. It is still impor-
tant to maintain a good layer of embers.
Less heat - less wood - less air
Greater heat - more wood - more air
Soot deposits will settle on the glass if the stove is run too slowly or if your wood is not well
seasoned.

Other manuals for Morso 2110

Related product manuals