Table 4 Test Facility Conditions
Run
Room Temperature
(°F)
Barometric Pressure
(Hg)
Air Velocity
(ft/min)
Before
After
Before
After
Before
After
1
74.5
75.7
29.96
29.97
<50
<50
2
75.7
76.6
29.97
29.98
<50
<50
4
76.5
76.1
30.29
30.06
<50
<50
Table 5 Kindling and Start-up Fuel Description Summary
Birch Cordwood
Run
Kindling
Weight
Wet Basis
(lbs)
Start-up
Fuel Weight
Wet Basis
(lbs)
Residual
Start-up
fuel weight
(lbs)
1
1.54
2.31
1.19
3
1.66
2.48
0.88
Table 6 Fuel Measurement and Cordwood Description Summary TEST
Birch Cordwood
Run
Test Fuel
Wet Basis
(lbs)
Firebox
Volume
(ft
3
)
Fuel Loading
Density Wet
Basis
(lbs/ft
3
)
Test Fuel Dry
Basis (lbs)
1.
Test Fuel
Consumed
During Test
Dry Basis
(lbs)
1
5.09
0.505
10.08
4.197 + 0.979
4.601
1
2
5.94
0.505
11.76
4.945
4.945
3
5.09
0.505
10.08
4.227 + 0.985
4.64
1
4
6.19
0.505
12.26
5.091
5.091
1. Includes start-up and kindling fuel for high burn tests 1, 3